Marshall electronic V-R1041-IMD-TE4U Imd Configuration Submenu, Overview, IMD Protocol

Models: V-R1041-IMD-TE4U

1 28
Download 28 pages 2.34 Kb
Page 22
Image 22
IMD CONFIGURATION SUBMENU

On-Screen Menu (continued)

IMD CONFIGURATION SUBMENU

Overview

The V-R1041-IMD-TE4U features an In-Monitor Display (IMD) with the ability to display on-screen text and tally in three colors. IMD text, color, and alignment can be assigned to each screen locally using menu options (see below). Alternately, IMD text and tally can be remotely controlled via the RS-422/485 serial interface using several industry- standard protocols, including TSL and Image Video. Multiple V-R1041-IMD-TE4U monitors can be looped together and each addressed individually via the protocol. All menu features of the V-R1041-IMD-TE4U can also be controlled via the Marshall Network Controller box and Marshall protocol. (Contact Marshall Electronics for additional information).

Use the IMD Configuration submenu to configure various IMD parameters as described below.

IMD Configuration Submenu

IMD Protocol

Use the IMD Protocol menu option to choose the protocol with which the V-R1041-IMD-TE4U receives remote commands. Currently, four protocols are available. Contact Marshall Electronics for the latest protocol compatibility.

Image Video

Use the Image Video protocol setting when controlling the IMD from an Image Video tally controller or other controlling device which utilizes the Image Video protocol. The IMD #, IMD Name, and Baud Rate parameters must be set for each screen in conjunction with the controlling device.

TSL v4.0

Use the TSL v4.0 protocol setting when controlling the IMD from a TSL tally controller, or other controlling device which utilizes the TSL v4.0 protocol. The IMD # must be set for each screen in conjunction with the controlling device.

MEI

Use the Marshall protocol setting when controlling the V-R1041-IMD-TE4U using the Marshall Network Controller box. This protocol allows remote control of all features on the V-R1041-IMD-TE4U, including marker setup, video configuration, system configuration, and image adjustments (brightness, contrast, etc.). The IMD #, IMD Group #, and Baud Rate parameters must be set in conjunction with the Network Controller Box.

MEI-Image Video

This protocol setting accepts Image Video commands via the Marshall protocol, for use when an Image Video controller is connected to the Marshall Network Controller box.

22