THE GT-70 INDUSTRIAL TORCH DOES NOT CONTAIN BUTANE GAS WHEN PURCHASED

GAS REFILLING

Use only Master Ultratane™ Butane Fuel.

Shake gas container a few times to warm fuel up.

Make sure the Fuel Adjustment Knob is in the “OFF” position (fully clockwise).

Insert the Butane container nozzle tip vertically down into the unit gas valve refill opening. Use a pumping action for best results (Figure 1).

After filling, allow a few minutes for the gas to stabilize.

GAS

1

IGNITION

 

 

• Turn the Fuel Adjustment Knob counter-clockwise 1 full turn. (Figure 2)

FERMÉ

OFF

To Ignite: Push Safety Slide Bar up and hold while depressing Ignition

 

DESACTIVADO

Trigger (Figure 3). When you remove pressure from the ignition trigger,

 

 

unit will shut off instantly.

 

LOCK

 

ON

For Hands Free Mode: Push Hands Free ON/OFF slide switch foreword

 

ENGAGÉ

while depressing trigger (Figure 4). To shut off unit, return slide switch to

 

ACTIVADO

“OFF” position.

 

2

Note: It is sometimes difficult to ignite when the Air Control Ring covers

 

 

the air control holes. Adjust Accordingly.

 

 

FLAME ADJUSTMENT

 

 

• Adjust the torch flame length by turning the Fuel Adjustment Knob (+) (-)

 

LOCK

(Figure 2). Don’t make the flame too long as it will only waste the gas and

 

 

make the flame unstable.

 

 

• Turn the Air Control Ring forward to convert the blue pinpoint flame to a

 

3

soft/cooler flame. CAUTION: Air Control Ring can be very hot.

 

STORAGE

 

 

• Turn the Fuel Adjustment Knob clockwise to “OFF” position until snug.

 

 

Let tool cool down before storing.

 

 

To prevent gas leakage make sure Hands Free ON/OFF Slide switch is

 

 

returned completely to “OFF” position.

 

 

WARNINGS:

 

1.

Read Instructions Before Operation.

4

2.

Keep out of reach of children.

3.Do not touch flame guard when HOT!

4.Use only Master Ultratane™ Butane Fuel. Butane gas is extremely flammable, please handle with care.

5.Always point away from your face, eyes, and body when igniting or during operation.

6.Do not store under direct sunlight or anywhere temperature will exceed 104°F/40°C.

7.Make sure the Fuel Adjustment Knob is firmly closed (Figure 2) and flame is completely extinguished after using.

8.After using let tool cool down before storing.

9.Keep the nozzle clean from dust and do not drop the torch as these may cause malfunctions.

10.Do not continually use this tool for over 1 hour.

11.Never puncture or dispose of in a fire.

12.Read and follow all instructions and cautions on the fuel canister.

WARNING: This product, when used for soldering and similar applications, produces chemicals known to the state of California to cause cancer and birth defects or other reproductive harm.

WARNING: The Department of Transportation Hazardous Material Regulations forbid carriage of butane or other flammable gas products on passenger aircraft. Do not pack this item or any other flammable gas item, in any checked or carry-on baggage.

Contains flammable gas under pressure. Do not use near sparks or open flame. Do not puncture or incinerate container or store at temperatures above 120° F. Keep out of reach of children.

Page 2
Image 2
Master Appliance GT-70 manual GAS Refilling, Ignition, Flame Adjustment, Storage, Returned completely to OFF position