Master Lock B350EAI owner manual To Start Heater, Operation

Models: B350EAI

1 24
Download 24 pages 14.7 Kb
Page 8
Image 8
To Start Heater

OPERATION

8

Manual backgroundWARNING

Review and understand the warnings in the Safety Information Section. They are needed to safely operate this heater.

To Start Heater

1.Follow all ventilation and safety information.

2.Fill fuel tank with kerosene or No. 1 fuel oil.

3.Attach fuel cap.

4.Set thermostat dial to desired temperature. Note: Thermostat setting must be higher than surrounding air temperature.

5.Plug power cord of heater into a standard 220/240 volt, 50 hertz, grounded (earthed) outlet. Use an extension cord if needed. Use only a three-wire, grounded (earthed) extension cord.

Extension Cord Wire Size Requirements

Up to 100 feet (30.5 meters) long, use 16 AWG (1.0 mm2) conductor

101 to 200 feet (30.6 to 61 meters) long, use 14 AWG (1.5 mm2) conductor 201 to 300 feet (61.1 to 91.5 meters) long, use 12 AWG (2 mm2) conductor

6.The motor will start when power cord is plugged into outlet. The heater should ignite at once. If heater does not ignite, restart heater. To restart heater, wait 60 seconds, then push in safety control reset button. Safety control reset button is at rear of heater near power cord (see Figure 4).

Note: If starting heater for first time, you may need to restart heater several times before heater ignites. You may also have to do this after taking heater out of storage.

Safety Control

Reset Button

Figure 4 - Safety Control Reset Button

099565