Maytag HE21250T, HE31250T Converting the Lower Element contd, Instructions for Installation contd

Models: HE21282T HE21250S HE21250T HE21240S HE31240S HE31282T HE31250S HE31250T

1 32
Download 32 pages 56.63 Kb
Page 13
Image 13
Converting the Lower Element (cont'd)

Instructions for Installation (cont'd)

Converting the Lower Element (cont'd)

l.Before beginning the conversion turn "OFF" electric power supply to the water heater,

4.Lower Element: Lift out the tab as shown to unclip the terminal cover from the thermostat. The terminal cover

can now be removed from the thermostat.

i 'm

_WARNING

%G

HAZARD OF ELECTRICAL SHOCK! Before removing any access panels or servicing the water heater,

make sure the electrical supply to the water heater is turned "OFF". FAILURE TO DO THIS COULD

RESULT IN DEATH,

SERIOUS BODILY INJURY, OR

PROPERTY DAMAGE.

_'_

2. The convertible element is located behind the lower access panel of the water heater. Remove the two screws securing

the access panel, and remove panel.5. Remove the screws from terminal 2 of the element, and move the looped end of the wire aside.

3. Open the flap of insulation to expose the opening.

6. The buss bar is labeled 5500 W. Place the buss bar over ter-

 

minals 2 and 3 with the 5500 W visible, Install the extra

_

screw provided into terminal 3.

OI

 

13

Page 13
Image 13
Maytag HE21250T, HE31250T, HE31250S, HE31282T Converting the Lower Element contd, Instructions for Installation contd