SERVICE AND MAINTENANCE
Tank (Sediment) Cleaning
Sediment
Vent System Inspection
•Flue gases may escape if vent pipe is not connected.
•Be alert for obstructed, sooted or deteriorated vent system to avoid serious injury or death.
•Do not store corrosive chemicals in vicinity of water heater.
•Chemical corrosion of flue and vent system can cause serious injury or death
At least once a year a visual inspection should be made of the venting system. You should look for:
•Obstructions which could cause improper venting. The combustion and ventilation air flow must not be obstructed.
•Damage or deterioration which could cause improper venting or leakage of combustion products.
•Rusted flakes around top of water heater.
Be sure the vent piping is properly connected to prevent escape of dangerous flue gasses which could cause deadly asphyxiation.
Obstructions and deteriorated vent systems may present serious health risk or asphyxiation.
Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.
If after inspection of the vent system you found sooting or deterioration, something is wrong. Call a Maytag Service
Specialist at
Burner Inspection
Flood damage to a water heater may not be readily visible or immediately detectable. However, over a period of time a flooded water heater will create dangerous conditions which can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Contact the Maytag dealer from whom the appliance was purchased or call a Maytag Service Specialist at
At least once a year a visual inspection should be made of the main burner and pilot burner, see Figure 24.
You should check for sooting. Soot is not normal and will impair proper combustion.
Soot
FIGURE24.
Burner Cleaning
In the event your burner needs cleaning, following these instructions:
If inspection of the burner shows that cleaning is required, turn
the gas control knob clockwise ( ) to the “OFF” position, depressing slightly.
NOTE: The knob cannot be turned from “PILOT” to “OFF” unless knob is depressed slightly. DO NOT FORCE.
21