29" and 27" Wide Model Gas Dryer
PRODUCT MODEL NUMBERS | OVERALL DIMENSIONS | |
MGDC200X, MGDC300X, MGDX500X, | 29" Wide Model Dryer dimensions |
|
MGDX550X, MGDX600X, MGDX700X | the minimum ventilation openings in | |
|
| For closet installation, with a door, |
Gas supply: This dryer is equipped for use with Natural gas. Dryer |
| the top and bottom of the door are |
| required. Louvered doors with | |
can be converted to L.P. gas. When rigid pipe is used it should be |
| equivalent air ventilation openings |
1/2" IPS. When acceptable to the gas supplier and local codes, 3/8" |
| are acceptable. |
approved tubing may be used for lengths under 20 ft (6.1 m). |
|
|
For lengths over 20 ft (6.1 m), larger tubing should be used. Pipe- |
|
|
joint compounds resistant to the action of L.P. gas must be used. |
|
|
An individual manual shutoff valve must be installed within 6 ft (1.8 |
|
|
m) of the dryer in accordance with the National Fuel Gas Code ANSI |
|
|
Z223.1. |
|
|
Electrical: A |
| A. Large opening |
supply is required. A |
| B. Large opening |
| C. Wide opening | |
separate circuit are recommended. |
| |
| D. Wide opening hamper door | |
|
|
Water (Steam models only): The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result.
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
Hood styles: A & B are recommended. | C |
| Installation Spacing |
|
|
|
|
|
| |||||
B |
|
| 4" |
|
|
|
|
|
|
|
| 3"* |
| |
| (102 mm) |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| 14" max.* |
|
| (76 mm) |
| ||
|
|
|
|
|
|
|
|
|
| 48 in.2* |
|
| ||
|
|
|
|
|
|
|
|
|
| (356 mm) |
|
|
| |
A |
|
|
|
|
| 18"* |
|
|
| (310 cm )2 |
|
| ||
|
|
|
|
| (457 mm) |
|
|
|
|
|
|
| A. Recessed area | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 2½" |
|
|
|
|
|
|
|
|
| B. Side view - closet or confined area |
4" |
|
|
| (64 mm) |
|
|
|
|
|
|
|
|
| C. Closet door with vents |
|
|
|
|
|
|
|
|
|
| 24 in.2 * | 3"* |
| ||
(102 mm) | A. Louvered hood |
|
|
|
|
|
|
| (155 cm )2 | (76 mm) |
| |||
4" |
| B. Box hood |
|
| 1" | 29" | 1" | 1"* | 27¾" |
|
|
|
| |
| C. Angled hood (acceptable) |
|
|
|
|
| ||||||||
(102 mm) |
|
| (25 mm) | (737 mm) | (25 mm) (25 mm) (705 mm) |
|
|
|
| |||||
|
|
|
|
|
|
|
| *Required spacing | ||||||
|
|
|
|
|
| A |
|
| B |
| C |
| ||
|
|
|
|
|
|
|
|
|
|
| ||||
The vent system chart provides venting requirments that will help to |
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
| ||||||
achieve the best drying performance. |
|
|
|
|
|
|
|
|
|
|
| |||
Vent system chart: |
|
|
|
|
| 27" Wide Model Dryer dimensions |
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
NOTE: Side and bottom exhaust installations for 27" have a 90° turn |
|
|
|
|
|
|
|
|
| |||||
inside the dryer. To determine maximum exhaust length, add one 90° |
|
|
|
|
|
|
|
|
| |||||
turn to the chart. |
|
|
|
|
|
|
|
| 23¾" |
|
|
|
| |
|
| Vent System Chart |
|
|
|
|
| (603 mm) |
|
|
|
| ||
|
|
|
| 43" |
|
|
| 43" |
|
|
| |||
Number of |
| Type | Box/louvered | Angled |
| (1092 mm) |
|
|
| (1092 mm) |
|
| 13¾" | |
|
|
|
|
|
|
|
|
|
| |||||
90° turns or |
| of vent | hoods | hoods |
|
|
|
|
|
|
|
| (349 mm) | |
elbows |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 | Rigid metal | 64 ft. (20 m) | 58 ft. (17.7 m) |
| *291/2" |
|
|
|
| *291/2" |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |||
1 |
|
|
|
|
| (749 mm) |
| 27" |
| (749 mm) | 27" |
| ||
Rigid metal | 54 ft. (16.5 m) | 48 ft. (14.6 m) |
|
|
|
|
|
|
|
| ||||
|
| (687 mm) |
|
|
|
| (687 mm) | A. Large opening | ||||||
|
|
|
|
|
|
| A |
|
|
|
| B |
| |
2 | Rigid metal | 44 ft. (13.4 m) | 38 ft. (11.6 m) |
|
|
|
|
|
|
| B. Wide opening hamper door | |||
| Installation Spacing |
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| 3"* | |||
3 | Rigid metal | 35 ft. (10.7 m) | 29 ft. (8.8 m) |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| 14"max.* |
|
| (76 mm) | ||||||
|
|
|
|
|
|
|
|
|
| 48 in.2* |
| |||
4 | Rigid metal | 27 ft. (8.2 m) | 21 ft. (6.4 m) |
|
|
|
|
| (356 mm) |
|
| |||
| 18"* |
|
|
| (310 cm )2 |
|
| |||||||
|
|
|
|
|
| (457 mm) |
|
|
|
|
|
|
|
|
|
| Vent System Chart |
|
|
|
|
|
|
|
|
|
|
| |
(29" Wide Long Vent Models Only) |
|
|
|
|
|
|
| 24 in2.* |
|
| ||||
Number of |
| Type | Box/louvered, or |
|
|
|
|
|
|
|
| 3"* | ||
90° turns |
| of vent | Angled hoods |
|
|
|
|
|
|
| (155 cm )2 |
| (76 mm) | |
or elbows |
|
|
|
|
| 1" | 27" | 1" | 1"* | 29¼" | 5½"* |
|
|
|
0 |
| Rigid metal | 120 ft. (36.6 m) |
|
|
|
| |||||||
|
| (25 mm) | (686 mm) | (25 mm) (25 mm) (743 mm) (140 mm) |
|
| ||||||||
Installation Spacing |
|
|
|
| A |
|
| B |
|
| C |
| ||
1 |
| Rigid metal | 110 ft. (33.5 m) |
|
|
|
|
|
| A. Recessed area | ||||
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
| *Required spacing |
|
|
|
|
|
| B. Side view - closet or confined area | |
2 |
| Rigid metal | 100 ft. (30.5 m) |
|
|
|
|
|
|
| C. Closet door with vents | |||
|
|
|
|
|
|
|
|
|
|
| ||||
3 |
| Rigid metal | 90 ft. (27.4 m) | Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use | ||||||||||
|
|
|
|
| ||||||||||
4 |
| Rigid metal | 80 ft. (24.4 m) | the fewest number of elbows and turns. Use the fewest 90° turns possible. |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Do not use vent runs longer than specified in vent length chart. | |
5 | Rigid metal | 70 ft. (21.3 m) | ||
Determine the number of elbows you will need. | ||||
|
|
| ||
|
|
|
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. W10096984A |