Connect Vent

1.Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a 4" (10.2 cm) clamp.

2.Move dryer into its final location. Do not crush or kink vent.

3.(On gas models) Check that there are no kinks in the flexible gas line.

4.Once the exhaust vent connection is made, remove the corner posts and cardboard.

Level Dryer

Check the levelness of the dryer. Check levelness first side to side, then front to back.

If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs up or down and check again for levelness.

Complete Installation

1.Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.

2.Check that you have all of your tools.

3.Dispose of/recycle all packaging materials.

4.Check the dryer’s final location. Be sure the vent is not crushed or kinked.

5.Check that the dryer is level. See “Level Dryer.”

6.In the U.S.A.

„For power supply cord installation, plug into a grounded outlet. For direct wire installation, turn on power.

In Canada

„Plug into a grounded 4 prong outlet. Turn on power.

7.Remove any protective film or tape remaining on the dryer.

8.Read “Dryer Use.”

9.Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust.

10.Set the dryer on a full heat cycle (not an air cycle) for 20 minutes and start the dryer.

If the dryer will not start, check the following:

„Controls are set in a running or “On” position.

„Start button has been pushed firmly.

„Dryer is plugged into a grounded outlet and/or electrical supply is on.

„Household fuse is intact and tight, or circuit breaker has not tripped.

„Dryer door is closed.

This dryer automatically runs an installation diagnostic routine at the start of its first cycle.

„If you receive an L2 code, there may be a problem with your home power supply keeping the dryer’s heater from turning on. See “Troubleshooting”.

„If you receive an AF code, your dryer vent may be cushed or blocked. See “Troubleshooting”.

NOTE: You may notice a burning odor when the dryer is first heated. This odor is common when the heating element is first used. The odor will go away.

20

Page 20
Image 20
Maytag W10057349A Connect Vent, Complete Installation, U.S.A, Canada, If the dryer will not start, check the following