4.Mark on the countertop the location of the 4 mounting holes at the corners of the cooktop. Set cooktop aside on a covered surface.

AA

A. Mounting holes

5.Use ¹⁄₈" (3 mm) drill bit and drill 4 pilot holes.

6.Using 2 or more people, gently place the cooktop in cutout so that the cooktop mounting holes align with the 4 pilot holes.

7.Attach the cooktop base to countertop with the 4 mounting screws.

8.Reattach the cooktop to the cooktop base using the 4 screws.

9.Replace the coil elements and burner bowls.

Line up openings in the burner bowl with the coil element receptacle.

Holding the coil element as level as possible, slowly push the coil element terminal into the receptacle.

When the terminal is pushed into the receptacle as far as it will go, push down the edge of the coil element opposite the receptacle.

Make Electrical Connection

Electrical Connection OptionsWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper wire.

Electrically ground cooktop.

Failure to follow these instructions can result in death, fire, or electrical shock.

This cooktop is manufactured with the frame connected to the bare ground wire. Connect the cooktop cable to the junction box through the UL listed or CSA approved conduit connector.

1.Disconnect power.

2.Remove junction box cover, if present.

3.Connect the flexible cable conduit from the cooktop to the junction box using a UL listed or CSA approved conduit connector.

4.Tighten screws on conduit connector if present.

5.See “Electrical Connection Options” chart to complete installation for your type of electrical connection.

Electrical Connection Options

If your home has:

And you will be

Go to Section:

 

connecting to:

 

4-wire

A fused

4-Wire Cable from

 

disconnect or

Home Power

 

circuit breaker

Supply

5"

box

 

 

 

(12.7 cm)

 

 

3-wire

A fused

3-Wire Cable from

1"

disconnect or

Home Power

circuit breaker

Supply

(2.5 cm)

 

 

box

3" Manual background

(7.6 cm)

5

Page 5
Image 5