Installation spacing for recessed area or closet installation
nAll dimensions show recommended and minimum spacing allowed.
nAdditional spacing should be considered for ease of installation and servicing.
nAdditional clearances might be required for wall, door, floor moldings, and dryer venting.
nAdditional spacing should be considered on all sides of the dryer to reduce noise transfer.
nFor closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
nCompanion appliance spacing should also be considered.
Custom undercounter installation (dryer only):
331/4"
(845 mm)
Recessed or closet installation – Stacked with stack kit:
12"
(305 mm)
3"
(76 mm)
661/4"
(1683 mm)
51/4" | 3" | |
(133 mm) | ||
(76 mm) | ||
|
1"
1" (25 mm) (25 mm)
48in.2
(310 cm2)
24in.2
(155 cm2)
1"
233/8" (25 mm)
1" (594 mm) (25 mm)
Recessed or closet installation (dryer only):
Mobile home - Additional installation requirements:
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 24, HUD Part 280).
Mobile home installations require:
18"9"min (457(229mm))
3"
(76 mm)
48in.2
(310 cm2)
nMetal exhaust system hardware, available for purchase from your dealer.
nSpecial provisions must be made in mobile homes to introduce outside air into dryer. Openings (such as a nearby window) should be at least twice as large as dryer exhaust opening.
3" | 3" | |
(76 mm) | ||
(76 mm) | ||
|
1"
1" (25 mm) (25 mm)
24in.2
(155 cm2)