Merco Savory 86002 service manual ErNN

Models: 86002

1 12
Download 12 pages 47.92 Kb
Page 11
Image 11
ErNN

THERMOCOUPLE FAULT DETECTION (CONT”D)

If a fault is detected in any bin, the display for that bin will show “ErNN” where “NN” is a numeric error code. This two digit error code uses the first digit for the upper heater zone. If a short is detected, the digit will be a “1”, if an open is detected a “2” will be displayed. If the heater zone is operating properly, a “0” will be displayed.

 

 

 

ErNN

 

UPPER HEATER ZONE

 

 

 

LOWER HEATER ZONE

 

 

 

Some Examples:

 

 

 

 

 

Er01

Indicates

Upper heater zone is good. Lower heater zone TC short detected.

Er02

Indicates

Upper heater zone is good. Lower heater zone TC open detected.

Er10

Indicates

Upper heater zone TC short detected. Lower heater zone is good.

Er20

Indicates

Upper heater zone TC open detected. Lower heater zone is good.

Er22

Indicates

Upper and Lower heater zone TC’s detected open.

Cold

Indicates

Temperature of heater zone is below set point.

Hot

Indicates

Temperature of heater zone is above set point.

Once and error is indicated for a heater zone the affected heater is shut off.

The only way to clear an error indication is by cycling the power off then on again.

To reset the holding bin controller to the factory configuration, hold down the upper-left “Bin” button while powering on the controller. Release the “Bin” button as soon as the displays illuminate. This resets the following settings:

All product names

Upper and lower temperature for each product

“Expiration” and “Cook More” time for each product

NOTE: For additional information concerning Menu and Product programming, please refer to Merco Holding Cabinet Installation & Operation Manual.