
230 V/ 400 V Combi Machines
Combi models come with a CEE
If a
For 380/415 V operation connect to 2 phases + zero and earth lead
L1 black
L2 brown
zero/neutal lead blue
earth lead yellow/green
Caution: Have machine connected to power mains by a qualified electrician only!
Neon Control Light
Welding step selector
Mains on/off switch
Earth cable socket
Central coupling KZ 2 for welding gun
Wire feed regulator
Weld time pot
Dwell time pot
Welding mode selector
4 Installing the Wire Spool
4.1 Disconnect from power mains
Place wire spool onto spool carrier so that wire runs off clockwise.