INTRODUCTION MS2221 / MS2222 SCANNER DESIGN SPECIFICATIONS
 Design Specifications 
Operational   
Light Source:  VLD 650 nm 
Peak Laser Power:   <1.5 mW 
Maximum IR LED Output:  50μW per IEC 60825-1 measurement procedure 
 Horizontal Depth of Field:   0 mm - 152 mm (0”- 6”) for 0.33 mm (13 mil) Bar Code 
Vertical Depth of Field:   0 mm - 216 mm (0”- 8.5”) for 0.33 mm (13 mil) Bar Code 
Scan Speed:  5400 Scan Lines per Second 
No. of Scan Lines:  54 (38 Horizontal / 16 Vertical) 
Motor Speed:  6000 / 6000 RPM  (Horizontal / Vertical ) 
Min Bar Width:  0.127 mm (5.0 mil) 
Scan Zone:  360° 
Decode Capability:  All Standard 1-D Bar Codes, RSS-14, RSS-Expanded, and RSS-14 Limited Bar Codes 
System Interfaces:  RS232, Aux RS232, IBM468x/469x, USB, and OCIA 
Print Contrast:  35% Minimum Reflectance Difference 
No. Characters Read:  Up to 80 data characters.  Maximum number will vary based on symbology and density. 
Beeper Operation:  7 Tones or No Beep; 3 Volume Settings 
Blue  Laser ON, Ready to Scan 
Indicators (LED):   White   Good Read, Decoding 
Mechanical   
MS2221 L x W x H:  399 mm (15.7")  Length  292 mm (11.5")  Width  130 mm (5.12")  Tower Height 
MS2222 L x W x H:  353 mm (13.9")  Length  292 mm (11.5")  Width  130 mm (5.12")  Tower Height 
Depth (Below Counter):  100 mm (3.9"), All Models 
Weight (with Platter):  MS2222, 5.98 kg (13.20 lbs.)  MS2221, 9.28 kg (20.5 lbs.) 
Electrical   
Voltage Supply: 2A @ +5.2V / 1A @ +12V  
Power:  Operating, 11.9 Watts   Standby, 3.25 Watts 
Current:  Operating, 1.5A @ 5.2V / 0.3A @ 12V  Standby, .44A @ 5.2V / 0.08A @ 12V 
Current Limits on Integrated    
Scale and/or Scale Display:  Do not exceed maximum current of 12V @ 0.7A / 5V @ 0.2A 
DC Transformers:  Class II; 5.2VDC @ 2A; 12VDC @ 1A 
For Regulatory Compliance Information refer to pages 54 - 56. 
Environmental   
Operating Temperature:  0°C to 40°C (32°F to 104°F) 
IP Rating:  IP 55 
Light Levels:  4842 Lux (450 footcandles) 
Storage Temperature:  -40°C to 60°C (-40°F to 140°F)  
Humidity:  5% to 95% Relative Humidity, Non-Condensing 
Contaminants:  Sealed to resist airborne particulate contaminants. 
Ventilation: None Required 