 24 
TROUBLESHOOTING GUIDE 
Symptoms  Possible Cause(s)  Solution 
All Interfaces 
The unit is trying to 
scan a particular 
symbology that is not 
enabled. 
UPC/EAN, Code 39, Interleaved 
2 of 5, Code 93, Code 128 and 
Codabar are enabled by default. 
Verify that the type of bar code 
being read has been selected 
The unit powers 
up but does not 
scan and/or 
beep. 
The scanner has been 
configured for a 
character length lock, 
or a minimum length 
and bar code being 
scanned does not 
satisfy the configured 
criteria. 
Verify that the bar code that is 
being scanned falls into the 
criteria.  
Typical of Non-UPC/EAN codes. 
The scanner defaults to a 
minimum of 4 character bar 
code. 
The unit scans 
a bar code, but 
locks up after 
the first scan 
(the white LED 
stays on). 
The scanner is 
configured to support 
some form of host 
handshaking but is not 
receiving the signal. 
If the scanner is setup to support 
ACK/NAK, RTS/CTS, 
XON/XOFF or D/E, verify that 
the host cable and host are 
supporting the handshaking 
properly. 
The unit scans 
but the data 
transmitted to 
the host is 
incorrect. 
The scanner’s data 
format does not match 
the host system 
requirements. 
Verify that the scanner’s data 
format matches the format 
required by the host.  
Make sure that the scanner is 
connected to the proper host 
port. 
There are 
multiple scans 
upon 
presentation of 
code. 
The same symbol 
timeout is set too 
short. 
Adjust the same symbol timeout 
for a longer time increment.