SCANNER INSTALLATION 
 Additional Settings for EAS Equipped Models All MS9590 models equipped with EAS capabilities have an EAS designation in 
their model numbers (example: MS9590-38-EAS).  The cable supplied with these 
units will have additional wires for Checkpoint Device connections. 
Figure 10.  EAS Cable Samples 
SW1 and SW2 are the switch banks inside the Checkpoint Device that set the 
deactivation range.  The following is a list of Checkpoint recommended switch 
bank settings. 
Checkpoint Recommended Switch Bank Settings 
SW1   SW2 
Switches 1, 4, 5, and 6  ON  Switches 1, 4, 5, and 6   ON 
Switches 2 and 3  OFF  Switches 2 and 3  OFF 
Figure 11 shows the location of the 
EAS deactivation area.  
It is important to pass the entire tag 
through this area to deactivate the 
security tag. 
Figure 11.  EAS Deactivation Area