600-HP Specifications
1. Recommended maximum operating
frequency range. Response depends on
loading conditions and room acoustics.
2. Free field, measured with 1/3-octave
frequency resolution at 4 meters.
3. Measured with music referred to 1
meter, half-space loading.
4. Power handling is measured under
AES standard conditions: transducer
driven continuously for two hours with
band-limited noise signal having a 6
dB peak-average ratio.
5. Amplifier wattage rating based on the
maximum unclipped burst sine-wave
rms voltage that the amplifier will
produce for at least 0.5 seconds into
the nominal load impedance: both
channels 67 V rms into 4 ohms.
6. Peak power based on the maximum
unclipped peak voltage that the
amplifier will produce for at least 100
milliseconds into the nominal load
impedance: both channels 95 V pk into
4 ohms.
7. Measured using pink noise as an input
signal.
8. AC power cabling must be of sufficient
gauge so that under burst current rms
conditions, cable transmission losses
do not drop voltage below specified
operating range at the speaker.
Operating Frequency Range1
Frequency Response2
Phase Response
Maximum Peak SPL3
Dynamic Range
Type
Maximum Common Mode Range
Connectors
Input Impedance
Wiring
DC Blocking
CMRR
RF Filter
TIM Filter
Nominal Input Sensitivity
Input Level
Type
Output Power5
Total Output6
THD, IM, TIM
Load Capacity
Cooling
Connector
Automatic Voltage Selection
Safety Agency Rated Operating Range
Turn-on and Turn-off Points

Current Draw:

Idle Current
Max Long-Term Continuous Current (>10 sec)7
Burst Current (<1 sec)7,8
Ultimate Short-Term Peak Current Draw7
Inrush Current
36 Hz - 150 Hz
39 Hz - 130 Hz ±4 dB
46 Hz - 120 Hz ±30°
138 dB
>110 dB
360° (single unit); varies with number of units and configuration
Two 15" cone drivers

Nominal impedance: 4

Voice coil size: 4"

Power handling capability: 1200 W (AES)4
Differential, electronically balanced
±15 V DC, clamped to earth for voltage transient protection
Female XLR input with male XLR loop output or VEAMall-in-one
connector (integrates AC, audio and network)
10 k differential between pins 2 and 3
Pin 1: Chassis/earth through 220 k, 1000 pF, 15 V clamp network to
provide virtual ground lift at audiofrequencies
Pin 2: Signal +
Pin 3: Signal -
Case: Earth ground and chassis
None on output, DC blocked through signal processing
>50 dB, typically 80 dB (50 Hz–500 Hz)
Common mode: 425 kHz
Differential mode: 142 kHz
Integral to signal processing (<80 kHz)
0 dBV (1 V rms, 1.4 V pk) continuous is typically the onset of limiting
for noise and music
Audio source must be capable of producing a minimum of +20 dBV
(10 V rms, 14 V pk) into 600 inorder to produce maximum peak
SPL over the operating bandwidth of the loudspeaker

Two-channel complementary MOSFET output stages

(class AB/H)

2250 W

4500 W peak

<.02%
4 each channel
Forced air cooling, two fans total (one ultrahigh-speed reserve fan)

250 V AC NEMA L6-20 twistlock, IEC-309 male, PowerCon, or

VEAM

Automatic, two ranges, each with high-low voltage tap

(uninterrupted)

95 V AC - 125 V AC; 208 V AC - 235 V AC, 50/60 Hz

85 V AC - 134 V AC; 165 V AC - 264 V AC, 50/60 Hz

0.64 A rms (115 V AC); 0.32 A rms (230 V AC); 0.85 A rms (100 V AC)

8.8 A rms (115 V AC); 4.4 A rms (230 V AC); 10 A rms (100 V AC)

19 A rms (115 V AC), 9.5 A rms (230 V AC), 22 A rms (100 V AC)

39 A (115 V AC), 20 A (230 V AC), 45 A (100 V AC)

7 A pk (115 V AC), 7 A pk (230 V AC), 10 A pk (100 V AC)

Equipped with two-conductor twisted-pair network, reporting

all operating parameters of amplifiers to system operator’s host

computer

Notes:
meyer sound laboratories inc.
2832 San Pablo Avenue
Berkeley, CA 94702
T: +1 510 486.1166
F: +1 510 486.8356
info@meyersound.com
www.meyersound.com
600-HP: 04.149.004.01 A
©2005
Meyer Sound Laboratories Inc.
All rights reserved.
architect specifications
The loudspeaker shall be a self-powered, sub-bass system that
may be deployed as either a flown or a ground-stacked unit. The
transducers shall consist of two 15-inch cone drivers (4-inch
voice coil) each rated to handle 1200 AES* watts.
The loudspeaker shall incorporate internal processing electronics
and a two-channel amplifier. Each amplifier channel shall be
class AB/H with complementary MOSFET output stages. Burst
power shall be 2250 watts (4500 watts peak) with a nominal 4-
ohm resistive load. Distortion (THD, IM, TIM) shall not exceed
0.02%. Protection circuits shall include TruPower limiting. The
audio input shall be electronically balanced with a 10 kOhm
impedance and accept a nominal 0 dBV (1 V rms) signal (20 dBV to
produce maximum SPL). Connectors shall be XLR (A-3) type male
and female or VEAM all-in-one. RF filtering shall be provided,
and CMRR shall be greater than 50 dB (50 – 500 Hz).
Performance specification for a typical production unit shall be as
follows, measured at 1/3-octave resolution: Operating frequency
range shall be 36 Hz to 150 Hz. Phase response shall be ±30° from
46 Hz to 120 Hz. Maximum peak SPL shall be 138 dB at 1 meter,
half-space loading.
The internal power supply shall perform automatic voltage
selection, EMI filtering, soft current turn-on and surge
suppression. Powering requirements shall be nominal 100 V,
110 V or 230 V AC line current at 50 Hz or 60 Hz. UL and CE
operating voltage ranges shall be 95 to 125 V AC and 208 to 235
V AC. Current draw during burst shall be 19 A rms at 115 V AC,
9.5 A rms at 230 V AC, and 22 A rms at 100 V AC. Current inrush
during soft turn-on shall not exceed 7 A at 115 V AC. AC power
connectors shall be NEMA L6-20, IEC 309 male, PowerCon, or
VEAM all-in-one.
The loudspeaker shall optionally incorporate the electronics
module for Meyer Sound’s RMS remote monitoring system.
Loudspeaker components shall be mounted in a premium birch
plywood enclosure with a black textured hard-shell finish. The
unit shall accommodate an optional rigging frame, as well as
options with and without carrying handles. Dimensions shall be
41.4" w x 22 5" h x 22.0" d (1052 mm x 572 mm x 559 mm). Weight
shall be 182 lbs (82.55 kg). Weight with rigging shall be 215 lbs
(97.52 kg).
The loudspeaker shall be the Meyer Sound 600-HP compact high-
power subwoofer.
*Driven continuously for two hours with band-limited noise
signal having a 6 dB peak-average ratio.
Acoustical
Coverage
Transducers
Audio Input
Amplifier
AC Power
RMS Network
EuropeanOffice:
MeyerSoundLab. GmbH
CarlZeissStrasse13
56751Polch,Germany
MadebyMeyerSound Laboratories
Berkeley,CaliforniaUSA