Accessing the RemoteVision control panel

RemoteVision (optional accessory)

Accessing the RemoteVision control panel

￿Touch the access button "￿" so it turns yellow.

￿Note the position of the ￿ button, but do not touch.

￿Touch the access button "￿" again so it turns white.

Only the access button "￿" is visible.

￿Place one finger on the position of the ￿ button and hold (the ￿ button will not be visible).

￿While holding down the ￿ button, press the access button "￿" once. Keep holding the ￿ button down until the following appears in the display (approx. 5 seconds).

Access to the Custom settings mode is now active for approximately 10 seconds.

￿Tap the ￿ button until ￿ appears in the display.

￿Touch the access button "￿" to confirm.

See the table on the following page for a description of each setting in the display.

￿Use the ￿ or ￿ buttons to select the RemoteVision options.

The module has been connected to the network when ￿ # appears in the display.

If ￿ # does not appear, refer to the "Network options" section of the XKM 2000 Installation Instruction manual.

￿Press and hold the access button "￿" for 2 seconds to confirm the change.

￿To return to the main menu, tap the ￿ button until a solid ￿ - appears in the display.

￿Press the access button "￿" to confirm.

￿Tap the ￿ button until a ￿ appears in the display.

￿Touch the access button "￿".

You have left the Custom settings mode.

When you are in the Custom settings mode the door alarm is turned off automatically. Once the door is closed it is reactivated.