Installation - venting

Table II

Effective duct

Internal diameter or

length (m)

edge length (mm)

 

 

0-20

100

20-30

110

30-43

120

43-60

130

 

 

Flexible ducting has been used for the following example.

Example:

Exhaust connection, left . . . . . . . 6.0 m Length (L) . . . . . . . . . . . . . . . . . . 0.6 m Lower radius (R = 400 mm) . . . . 0.4 m Height (H) . . . . . . . . . . . . . . . . . . 1.5 m Upper radius (R) . . . . . . . . . . . . . 0.5 m Wall pipe with louvred vent . . . . . 3.8 m Effective duct length . . . . . . . . . 12.8 m

Result:

A duct diameter of 100 mm is adequ- ate since the effective length is less than 20 m as specified in Table II.

25

Page 25
Image 25
Miele T1520 operating instructions Example, Result, Effective duct Internal diameter or Length m