To maximize the fiber cable distance, use one meter of CAT 5 UTP cable when connecting directly to a node (subject to fiber budget of 16dBm and collision domain restrictions). In
100m of CAT 5 UTP and:
42Km of
415Km of
440Km of
470Km of
4100Km of
4 | 1300nm wavelength | 4 | 1300nm wavelength |
4 | 62.5/125 micron diameter | 4 | 9/125 micron diameter |
4 Launch power: | 4 Launch power: | ||
4 | 4 | ||
4 | 1300nm wavelength | 4 | 1550nm wavelength |
4 | 9/125 micron diameter | 4 | 9/125 micron diameter |
4 Launch power: | 4 Launch power: 0dBm minimum | ||
4 | 4 |
41550nm wavelength
49/125 micron diameter
4Launch power: 1.8dBm minimum
4
M
The
4For a hub/repeater, use a swap cable (pins are connected 1 to 3, 2 to 6, 3 to 1, and 6 to 2).
4For a workstation/PC, use a
Cables used when the switch is in the MDI position (the"right" position):
4For a hub/repeater, use a
4For a workstation/PC, use a swap cable (pins are connected 1 to 3, 2 to 6, 3 to 1, and 6 to 2).
1 2 | 3 | 4 | 5 6 7 8 | MDI | |
p‹“@Q]rxK |
|
| @@@@@@@@@@@@@@@@@@@p‹“@Q]txK | ||
p‹“@R]rxM |
|
|
|
| p‹“@R]txM |
p‹“@S]txK |
|
|
|
| p‹“@S]rxK |
p‹“@V]txM |
|
|
|
| p‹“@V]rxM |
Ins ta lla tio n
1.Make any configuration changes to the module DIP switch settings.
2.Remove cover plate from MCS chassis.
3.Slide module into a slot through the card guides.
4.Firmly seat module into
5.Secure module with thumbscrews located on module faceplate.
6.Plug in network connections.
Note: There is no need to power off the Media Conversion System.
Dia g no s tic LEDs a nd Co nd itio ns Ind ica ted
There are four LEDs for both UTP and fiber ports:
4D = Duplex; On indicates Full Duplex.
4A = Activity; On indicates receiving packets at port.
4S = Speed; On indicates rate is 100 Mbs.
4L = LINK; On indicates an active connection at port.
1
2
3
4
5
6
7
7- pin DIP Switch |
|
Switch | Switch |
LEDs | |
RJ | RJ |
Connector | Connector |
Fig ur e 2 . Ins id e | o f the M |
Dip S w itch Fea tur es (Fig ur e 2 )
Speed and Half/Full Duplex or Auto Negotiation may be manually selected using the
All switches must be in the up position to utilize SNMP feature selection. Fiber ports operate at 100Mbs only.
Port 1 is on the left. Port 2 is on the right.
| Switch 1 | Switch 2 | Switch 3 |
|
| Speed |
| ||
Up Position | Enable Port 1 | Enable Port 2 | 100Mbs Port 1 |
|
Down Position | Disable Port 1 | Disable Port 2 | 10Mbs Port 1 |
|
|
|
|
|
|
| Switch 4 | Switch 5 | Switch 6 | Switch 7 |
| Speed | Duplex | Duplex | Packet size |
Up Position | 100Mbs Port 2 | FDX Port 1 | FDX Port 2 | 1518 Bytes |
Down Position | 10Mbs Port 2 | HDX Port 1 | HDX Port 2 | 1522 Bytes |