2-5. Electrical Service Guide
|
| 340 |
|
| 440 |
| |
|
|
|
|
|
|
| |
Input Voltage | 230 | 400 | 520 | 230 | 400 | 520 | |
|
|
|
|
|
|
| |
Input Amperes at Rated Output | 55 | 32 | 25 | 79 | 46 | 25 | |
|
|
|
|
|
|
| |
Max Recommended Standard Fuse or Circuit | 55 | 32 | 25 | 79 | 46 | 25 | |
Breaker Rating in Amperes | |||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
** Input Conductor Size in mm2 | 6 | 6 | 6 | 6 | 6 | 6 | |
** Grounding Conductor Size in mm2 | 6 | 6 | 6 | 6 | 6 | 6 |
** Power cord supplied with the unit is sized for 230V operation. Larger power cord may be required for cable lengths greater than 3 meters. C onsult national and local regulations.
2-6. Selecting a Location and Connecting Input Power
18 in (457 mm) for airflow
GND/PE
Connect First
1
OFF
ON
3060
100
160
1.6 220
2 2.54 5 Amp.
Have only qualified persons make this installation.
1 Rating Label
Supply correct input power.
GND/PE
L1 (U)
L2 (V)
L3 (W)