Specifications (Subject to change without notice.)

 

 

 

 

Welding

Max. Open-

 

 

 

 

 

 

 

 

 

 

 

 

Welding

Input

 

Amperage

Circuit

Amps Input at Rated Load Output, 50/60 Hz,

 

 

 

Dimensions

Net

Description

Mode

Power

Rated Output

Range

Voltage

208 V

220 V

230 V

400 V

440 V

460 V

575 V

KVA

KW

Weight

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CST-280,

Stick

3-Phase

280 A at 31.2 V,

5 – 280 A

77 VDC

35

34.2

17.8

14.7

14.6

10.2

H: 13-1/2 in

41 lb

220-230/460-

(SMAW)

 

35% Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

(343 mm)

(18.6 kg)

575 Dinse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W: 7-1/2 in

 

TIG

 

200 A at 28 V,

 

 

23.3

22.5

11.7

9.7

9.6

6.4

 

 

 

 

 

(191 mm)

 

CST-280,

(GTAW)

 

100% Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D: 18 in

 

220-230/460-

 

1-Phase

200 A at 28 V,

5 – 200 A

 

43.9

43

10.1

6.6

 

 

 

(457 mm)

 

575 Tweco

 

 

50% Duty Cycle*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150 A at 26 V,

 

 

32.7

32

7.3

4.6

 

 

 

 

 

100% Duty Cycle*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CST-280,

Stick

3-Phase

280 A at 31.2 V,

5 – 280 A

67 VDC

36

33

22.8

19.8

18

17.5

14

10.2

H: 13-1/2 in

41 lb

208-230/400-

(SMAW)

 

35% Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

(343 mm)

(18.6 kg)

460 Dinse

TIG

 

200 A at 28 V,

 

 

23.5

23

22.8

13.5

12

12.7

10.2

6.9

W: 7-1/2 in

 

 

 

 

 

(191 mm)

 

CST-280,

(GTAW)

 

100% Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D: 18 in

 

208-230/400-

 

1-Phase

200 A at 28 V,

5 – 200 A

 

43.9

43.3

43

9.9

6.5

 

 

 

(457 mm)

 

460 Tweco

 

 

50% Duty Cycle*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150 A at 26 V,

 

 

35

32.9

7.6

4.8

 

 

 

 

 

100% Duty Cycle*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Output ratings on 230 V single-phase are reduced to comply with CSA current limitation on input power cable.

CSA approval. 1P23M approval.

Control Panel

1. Output Light

1

2.On/Off Switch

3.Weld Process Selector Switch

4.Overtemp Light

5.Amperage Adjustment Control (5 – 280 Amps)

2

3

Performance Data

OFF

ON

POWER

4

 

 

 

 

 

 

 

 

 

125

150

 

 

 

 

 

 

 

 

 

100

175

 

 

 

 

X18

 

 

 

 

 

 

 

 

X

 

 

 

 

 

200

 

 

E

STIFF

 

 

 

 

 

 

K

 

 

 

 

 

 

 

IC

 

 

 

S

 

 

 

75

 

S

T

T

 

 

 

S

5

F

 

 

O

T

 

 

 

 

 

T C

 

 

 

 

 

F

I

 

 

 

S

 

 

 

 

 

 

K

 

225

T

 

 

 

 

 

 

S

E

50

 

 

 

 

 

 

 

X

 

G

 

 

 

 

 

 

 

 

 

 

I

 

 

 

 

 

 

T

X

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

F

I

1

 

 

R

 

 

 

F

 

0

 

250

 

A

 

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

T

 

 

 

 

 

 

25

 

 

 

I

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

280

 

 

 

 

 

 

 

 

 

 

PROCESS SELECT

AMP ADJUST

CST 280

 

 

 

 

 

 

 

 

 

 

MILLER ELECTRIC MFG. CO. APPLETON, WI

DUTY CYCLE CHART

 

300

 

 

 

 

 

 

 

 

 

 

3-Phase Operation

 

 

 

 

 

 

 

 

250

 

 

 

 

 

 

 

 

 

AMPERES

200

 

1-Phase Operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150

 

 

 

 

 

 

 

 

 

OUTPUT

100

 

 

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

10

20

30

40

50

60

70

80

90

100

% DUTY CYCLE

VOLT/AMP CURVE AT 150 AMPS

 

100

 

 

 

 

 

 

 

90

 

 

 

 

 

 

 

80

 

 

 

 

 

 

 

70

 

 

Setpoint

 

 

 

 

 

 

 

 

 

 

VOLTAGE

60

 

XX18

150 Amps

 

 

 

 

 

 

 

 

 

50

 

TIG

 

 

 

 

 

 

 

 

 

 

40

 

XX10

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XX18

 

 

 

 

 

 

 

 

 

 

20

 

 

 

Soft

 

 

 

10

 

 

TIG

XX18 Stiff,

 

 

 

 

 

 

 

 

 

0

 

 

 

XX10 Soft

XX10 Stiff

 

 

 

 

 

 

 

 

 

0

50

100

150

200

250

300

 

 

 

 

AMPERAGE

 

 

2

Page 2
Image 2
Miller Electric CST 280 manual Control Panel, Performance Data