SECTION 7 ± PARTS LIST

Item Dia.

Part

Description

 

 

No.

Mkgs.

No.

Quantity

 

 

 

 

Figure 7-1. Main Assembly

 

 

 

 

 

 

 

. . .

1

. . . . . . . . . . .

108 056 . . .

CASE SECTION, front end

. . 1

. . .

2

. . . . . . . . . . .

109 779 . . .

CASE

. . 1

. . .

3

. . . R6,7 . .

603 856 . . .

POTENTIOMETER, WW 10 turn 2 watt 10K ohm

. . 2

. . .

4

. . . . S7 . . . . 011 770 . . .

SWITCH, toggle SPDT 5 amp 125 volts

. . 1

. . .

5

. . . . S8 . . .

079 722 . . .

SWITCH, toggle SPDT 0.4 amp 2-4 volts dc

. . 1

. . . 6

. . LED1-3 .

083 850 . . .

LIGHT, indicator - red lens 2 volts

. . 3

. . .

7

. . . RC3 . .

097 867 . . .

RECEPTACLE, 17 pin MS-3102A-20-29P

. . 1

. . .

8

. . . . . . . . . . . .

. . . . . . . . . . .

NAMEPLATE (order by model & style number)

. . 1

. . .

9

. . . . R8 . . .

009 156 . . .

POTENTIOMETER, carbon 1 turn 2 watt 2.5K ohm

. . 1

. . . 10

. . . . S6 . . .

108 944 . . .

SWITCH, rotary - 0.5 amp 115 volts ac

. . 1

. . . 11

. . . . . . . . . . .

108 903 . . .

SHIELD, meter

. . 1

. . . 12

. . . A&V . .

108 453 . . .

METER, DC 0-200 MV

. . 2

. . .

. . .

. . . . . . . . . . .

108 904 . . .

ANCHOR, meter

. . 1

. . .

. . .

. . . PC5 . . .

124 002 . . .

CIRCUIT CARD, pendant

. . 1

. . .

. . .

. . . . . . . . . . .

038 785 . . .

STRIP, terminal 3 pole

. . 1

. . .

. . .

. . . . . . . . . . .

072 566 . . .

CONNECTOR, rect 8skt plug Amp 87159-8

. . 1

. . .

. . .

. . . . . . . . . . .

081 380 . . .

CONNECTOR, rect 14skt plug Amp 1-87159-3

. . 1

. . .

. . .

. . . . . . . . . . .

108 907 . . .

CONNECTOR, rect 13skt 1 row plug Amp 2-87499-3

. . 2

. . .

. . .

. . . . . . . . . . .

097 922 . . .

KNOB, pointer

. . 4

. . .

. . .

. . . . . . . . . . .

019 663 . . .

MOUNT, 15/16 OD x 3/8

. . 2

. . .

. . .

. . . . . . . . . . .

097 132 . . .

STAND-OFF, No. 6-32 x 3/8 inches

. . 4

. . .

. . .

. . . . . . . . . . .

094 484 . . .

STAND-OFF, No. 6-32 x 1 inch

. . 4

. . .

. . .

. . . . . . . . . . .

108 863 . . .

CABLE, interconnecting (consisting of)

. . 1

. . .

. . .

. . . . . . . . . . .

097 868 . . .

. CONNECTOR, circ 17skt plug Amphenol MS-3106A-20-29S

. . 1

. . .

. . .

. . . . . . . . . . .

039 734 . . .

. CONNECTOR, circ clamp str rlf Amphenol AN-3057-12

. . 2

. . .

. . .

. . . . . . . . . . .

090 263 . . .

. CABLE, pwr No. 18ga 18/c (order by ft)

. 15ft

. . .

. . .

. . . . . . . . . . .

097 866 . . .

. CONNECTOR, circ 17 pin plug Amphenol MS-3106A-20-29P

. . 1

. Hardware is common and

1

not available unless listed.

 

12

11

10

9

8

7

6

5

Figure 7-1. Main Assembly

2

3

4

ST-109 521

To maintain the factory original performance of your equipment, use only Manufacturer's Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor.

OM-533 Page 11

Page 12
Image 12
Miller Electric RPC-IP manual ± Parts List, Main Assembly

RPC-IP specifications

Miller Electric RPC-IP is a revolutionary power distribution and management system designed for advanced welding applications and industrial environments. This innovative equipment aims to enhance productivity, safety, and operational efficiency by optimizing the electrical power supply for multiple welding machines and other high-demand equipment.

One of the main features of the RPC-IP is its intelligent power distribution capabilities. It can manage and distribute power to multiple outputs while monitoring real-time load conditions. This makes it ideal for facilities with variable equipment demands, as it automatically adjusts power distribution to ensure optimal performance without overloads.

The RPC-IP is equipped with cutting-edge technology, including an integrated digital control panel that allows users to monitor and manage power usage intuitively. The control panel features a user-friendly interface that provides real-time data on energy consumption, load distribution, and system health. This level of transparency empowers operators to make informed decisions and minimize downtime.

Another notable characteristic of the RPC-IP is its advanced safety features. The system incorporates overload protection, short-circuit protection, and surge protection, ensuring that both equipment and personnel are safeguarded against power-related hazards. Additionally, the RPC-IP is compliant with stringent industry standards, which further enhances its reliability and user confidence.

Miller Electric has also prioritized connectivity in the RPC-IP design. The system supports remote monitoring and control via cloud-based technologies, enabling operators to access data and manage power distribution from virtually anywhere. This feature is particularly beneficial for multi-site operations where consistent oversight and management are crucial.

The RPC-IP is designed with versatility in mind, making it suitable for various applications, from small fabrication shops to large manufacturing facilities. Its modular design allows for customized setups, catering to specific operational needs.

In summary, Miller Electric RPC-IP is more than just a power distribution system; it is a comprehensive solution that integrates intelligent features, robust safety protocols, and seamless connectivity. This makes it an essential tool for any welding operation looking to improve efficiency, safety, and overall productivity in today’s competitive industrial landscape.