14. Press the RECORD RECORD key.
TEACH MODE
SERVO OFF
SENSOR AR
SELECT TYPE OF PARAMETER
BY FUNCT ION KEY
C–S TOUCH–S W–CHARA S–DATA >
15. Check settings of weld characteristics as follows:
a. Press the F4 F4 key to select the W–CHARA function.
POWER SOURCE WI RE
GMAW .035 .045 .062
SYNERGIC .035 .045 .062
GTAW–100 .035 .045 .062
GTAW–300 .035 .045 .062
USER REGI STER
DI F Y SC _ ED I T
AX I S ML4
TEACH
SERVO OFF
REGI ST MO
b. Press the F2 F2 key to select the MODIFY function.
RAT I NG OF POWER SOURCE
$WTBD3 1
TYPE SEPA . SYNER . T IG
RAT I NG CURRENT 300A
W–FEEDER RAT I NG 256 i .
PUSH RECORD AFTER SETT I NG
AX I S ML4
TEACH
SERVO OFF
c. Press the RECORD RECORD key.