WIRING INSTRUCTIONS
TITLE | ORBITAL SANDER |
| BULLETIN |
|
|
| a |
CRIMP LEAD 3 AND LEAD 7 TOGETHER IN Tl BEFORE INSERTING INTO SWITCH. ’ | ’ | I | |
|
CRIMP LEAD 4 AND LEAD 8 TOGETHER IN Tl BEFORE INSERTING INTO SWITCH.
INSERT TERMINALS T2 ON LEADS 5 AND 6 INTO BRUSH
HOLDER BEFORE ROUTING THRU WIRE TRAPS.
TUCK LEADS 7 AND 8 DOWN INTO THE
WIRE TRAP UNDER SWITCH.
TUCK LEADS 3 AND 4 DOWN
INTO THE WIRE TRAPS
BETWEEN SWITCH AND
FIELD.
NOTE: LEAVE NO SLACK ON FIELD
SIDE OF WIRE TRAPS. \
‘WIRE t4
BLACK
SCHEMATIC
NOTE:
All leads must be held to 5 l/8’.
All field leads to ba measured from and perpendicular to laminations. All lead lengths are before stripping.
1 TERMINAL DESCRIPTION 1
kiiii%TOR DESCRIPTION 1