314
Useful functions
Acceleration/deceleration time increment (Pr. 999="30(0.1s) or 31(0.01s)")
* The set value is changed for Pr. 21.
Parameter Name Initial set
increment Pr.999 = "30"
Pr.999 = "31"
Automatic parameter
setting
Refer to
page
7 Acceleration time 0.1s 0.1s 0.01s 101
8 Deceleration time 0.1s 0.1s 0.01s 101
16 Jog acceleration/deceleration
time 0.1s 0.1s 0.01s 95
21 Acceleration/deceleration time
increments 10
*1 *101
44 Second acceleration/
deceleration time 0.1s 0.1s 0.01s 101
45 Seco nd deceleration time 0.1s 0.1s 0.01s 101
264 Power-failure deceleration time
10.1s 0.1s 0.01s 156
265 Power-failure deceleration time
20.1s 0.1s 0.01s 156
582 Auxiliary motor connection-time
deceleration time 0.1s 0.1s 0.01s 283
583 Auxiliary motor disconnection-
time acceleration time 0.1s 0.1s 0.01s 283
REMARKS
When a parameter is set as the acceleration/deceleration time (0.1s), the 0.01s increment is dropped.
When a parameter is set as the acceleration/deceleration time (0.01s), the parameters are limited at the maximum value of the
parameter setting range. For example, Pr. 7 = "361.0s" when 0.1s increment is selected, and Pr. 7 = "360.00s" when 0.01s
increment is selected.