Parameter list
777 4mA input fault operation frequency 0 to 400Hz, 9999 0.01Hz 9999 182
778 Current input check filter 0 to 10s 0.01s 0 182
779 Operation frequency during
communication error 0 to 400Hz, 9999 0.01Hz 9999 216
799 Pulse increment setting for output
power
0.1kWh, 1kWh, 10kWh,
100kWh, 1000kWh 0.1 1kWh 138
PLC function
826
to
865 Parameter 11 to 50 for user 0 to 65535 1 0 260
867 AM output filter 0 to 5s 0.01s 0.01s 147
869 Current output filter 0 to 5s 0.01s 0.02s 147
870 Speed detection hysteresis 0 to 5Hz 0.01Hz 0Hz 133
872 Input phase loss protection selection 0, 1 1 0 162
Regeneration avoidance function
882 Regeneration avoidance operation
selection 0, 1, 2 1 0 298
883 Regeneration avoidance operation
level 300 to 800V 0.1V 380V/
760VDC*5 298
884 Regeneration avoidance at
deceleration detection sensitivity 0 to 5 1 0 298
885 Regeneration avoidance
compensation frequency limit value 0 to 30Hz, 9999 0.01Hz 6Hz 298
886 Regeneration avoidance voltage gain 0 to 200% 0.1% 100% 298
Free
parameter
888 Free parameter 1 0 to 9999 1 99 99 307
889 Free parameter 2 0 to 9999 1 99 99 307
Energy saving monitor
891 Cumulative power monitor digit
shifted times 0 to 4, 9999 1 9999 164
892 Load factor 30 to 150% 0.1% 100% 164
893 Energy saving monitor reference
(motor capacity)
0.1 to 55kW/
0 to 3600kW *2
0.01/0.1kW
*2
SLD/LD value
of Applied
motor Capacity
164
894 Control selection during commercial
power-supply operation 0, 1, 2, 3 1 0 164
895 Power saving rate reference value 0, 1, 9999 1 9999 164
896 Power unit cost 0 to 500, 9999 0.01 99 99 164
897 Power saving monitor average time 0, 1 to 1000h, 9999 1h 9999 164
898 Power saving cumulative monitor
clear 0, 1, 10, 9999 1 9999 164
899 Operation time rate (estimated value) 0 to 100%, 9999 0.1% 9999 164
Function Parameters
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting