PLC User's Manual - Positioning Control Edition
Built-in Positioning Functions
8 1-Speed Positioning - DRVI/DRVA Instruction
8.3 Drive To Absolute - DRVA Instruction
B - 118
8.3 Drive To Absolute - DRVA Instruction
8.3.1 Instruction Format
1. Instruction format
2. Data setting
*1. Setting range : -32,768 to +32,767 for 16-bit operation
: -999,999 to +999,999 for 32-bit operation
*2. Setting range : 10 to 32,767 Hz for 16-bit operation
For 32-bit operation, however, the setting range is as shown in the following table.
3. Devices
1 : Specify Y000, Y001, or Y002*1 transistor output from the main unit, or specify Y000, Y001, Y002*3, or
Y003*3 from a high-speed output special adapter*2.
*1. Y002 is not available in 14-point and 24-point type FX3G PLC.
*2. High-speed input/output special adapters can be connected only to the FX3U PLC.
*3. To use Y002 and Y003 with a high-speed output special adapter, connect a second high-speed output
special adapter.
Caution:
To use an FX3U Series main unit of relay output type, be sure to connect a high-speed output special
adapter. Differential line drive type outputs will be used for the outputs of the high-speed output special
adapter.
Operand type Description Data type
Specifies the number of output pulses (absolute address).*1
BIN16/32-bit
Specifies the output pulse frequency.*2
Specifies the pulse output number. Bit
Specifies the rotation direction signal output destination device number.
Pulse output destination Setting range
FX3U PLC High-speed output special adapter 10 to 200,000(Hz)
FX3G/FX3U/FX3UC PLC Main unit (transistor output) 10 to 100,000(Hz)
Operand
type
Bit device Word device Others
System user Digit designation System
user
Special
unit Index Con-
stant
Real
num-
ber
Char-
acter
string
Pointer
XYMTCSD.b KnX KnY KnM KnS T C D R U\GV Z Modify K H E ""P
33333333433 3 33
33333333433 3 33
13
23333
FNC 159
DRVA
DRIVE TO
ABSOLUTE
D
16-bit
instruction
9 steps DRVA
-
Continuous
execution
type
Instruction
symbol Execution condition 32-bit
instruction Instruction
symbol Execution condition
DDRVA
-
Continuous
execution
type
17 steps
Command
input
FNC 159
DRVA S
1
S
2
D
1
D
2
S
1
S
2
D
1
D
2
S
1
S
2
D
1
D
2