Mitsubishi Electronics HC900E manual Password lock commands, How to set the grade

Models: HC900E

1 5
Download 5 pages 21.67 Kb
Page 3
Image 3
8) Password lock commands

6)Keystone commands (Not executable in stand-by mode. Possible only to read during muting.)

The keystone commands are used for the keystone setting of this projector with the value. The value will vary depending on the installation conditions, etc.)

ITEM

ASCII

HEX

VALUE

KEYSTONE

KS

4Bh 53h

±20

How to set the grade

Use the ASCII codes to set the grade for setting data. Please refer to the table below for the HEX code.

ASCII

'+'

'–'

'0'

'1'

'2'

'3'

'4'

'5'

'6'

'7'

'8'

'9'

HEX

2Bh

2Dh

30h

31h

32h

33h

34h

35h

36h

37h

38h

39h

7)Remote commands (Not executable in stand-by mode. When the remote commands are sent while the splash screen is being displayed, the splash screen is only canceled.)

Some remote control operations can be achieved by the remote command codes. The remote commands have no data codes.

Button's name on remote

ASCII

HEX

 

 

+ VOLUME

r06

72h

30h

36h

– VOLUME

r07

72h

30h

37h

{

r53

72h

35h

33h

}

r2b

72h

32h

62h

$

r4f

72h

34h

66h

%

r59

72h

35h

39h

MENU

r54

72h

35h

34h

ENTER

r10

72h

31h

30h

AUTO POSITION

r09

72h

30h

39h

16:9/4:3

re2

72h

65h

32h

[Example] When displaying the MENU selection bar (Figures and symbols enclosed in quotation marks are ASCII codes.):

Sending commands

Status code from

Description

from the PC, etc.

the projector

 

30 30 72 35 34 0D

 

Command operating the same

'0' '0' 'r' '5' '4' ' '

 

as the MENU button

 

 

 

 

30 30 72 35 34 0D

Command receipt confirmation

 

'0' '0' 'r' '5' '4' ' '

(Command echo back)

 

 

 

8) Password lock commands

The password lock commands control the password lock. The password lock enabling or disabling command is sent with a 4-digit figure (password) added to the end of the data code. When the password lock is enabled or disabled successfully, the projector sends a return command comprising the data code, password, and “1” at the end. When enabling or disabling the password lock fails, it sends a return command with “0” at the end. There is no reconfirmation of the password.

ITEM

ASCII

HEX

 

VALUE

Password lock

PSLOCK

50h 53h 4Ch 4Fh

43h 4Bh

0****(Disabling), 2****(MENU ACCESS)

enabling/ disabling

 

 

 

 

****is a 4-digit figure (password).

3

Page 3
Image 3
Mitsubishi Electronics HC900E manual Password lock commands, How to set the grade