Mitsubishi Electronics MDT321S 1-28, Tiling, Power On Delay, Date & Time, Schedule, Advanced

Models: MDT321S

1 36
Download 36 pages 35.53 Kb
Page 28
Image 28
TILING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TILING demonstrates multiple screens. This feature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

provides a single large screen using up to 16 monitors.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

It will be able to divide up to 4 each H and V.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This requires you to feed the PC output into each of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

monitors through a distributor.

 

ADVANCED OPTION

 

 

TILING

 

 

 

 

 

 

 

 

 

 

H MONITORS: Select number of horizontal divide.

 

IR CONTROL

 

 

H MONITORS

 

1

 

 

 

 

 

 

V MONITORS: Select number of vertical divide.

TILING

TILING

 

 

V MONITORS

 

1

 

 

 

 

 

 

HEAT STATUS

 

 

FRAME COMP

 

YES

/

 

NO

POSITION: Select a position to expand the screen.

DATE & TIME

 

 

 

 

 

POWER ON DELAY

 

POSITION

 

 

1

 

 

 

 

 

 

 

 

SCHEDULE

 

 

ENABLE

 

 

YES

/

 

NO

 

 

ADVANCED OPTION RESET

 

 

 

 

FRAME COMP: Works in tandem with TILING to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:SEL SET :NEXT EXIT

:RETURN MENU :EXIT MENU

 

:SEL

+ -:ADJ

EXIT :RETURN

 

 

 

 

 

 

 

 

 

 

compensate for the width of the tile bezels in order to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

accurately display the image.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENABLE: Select “YES”, the monitor will expand the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

selected position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIP and STILL and “DYNAMIC” ZOOM mode will be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

disabled when “TILING” is activated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Information of status for COOLING FAN, BRIGHTNESS

 

ADVANCED OPTION

 

 

HEAT STATUS

 

 

 

 

 

 

 

 

 

and TEMPERATURE.

 

TILING

 

 

COOLING

FAN2

 

 

ON

 

 

 

COOLING FAN comes to run when inside temperature

 

IR CONTROL

 

 

COOLING

FAN1

 

 

ON

 

 

 

 

HEAT STATUS

HEAT STATUS

 

 

BRIGHTNESS

 

 

NORMAL

is over a guaranteed limit.

DATE & TIME

 

 

TEMPERATURE

 

 

 

 

 

 

 

 

 

POWER ON DELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCHEDULE

 

 

SENSOR 1

 

0.0 C

/ 32.0 F

BRIGHTNESS comes to be decreased when inside

 

ADVANCED OPTION RESET

 

SENSOR 2

 

0.0 C

/ 32.0 F

 

:SEL SET :NEXT EXIT

:RETURN MENU :EXIT MENU

 

 

EXIT :RETURN MENU :EXIT MENU

temperature is over guaranteed limit with cooling fun.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In this case warning is displayed on the screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADVANCED OPTION

 

 

POWER ON DELAY

 

 

 

 

 

 

 

 

Adjusts the delay time from “standby” to “power on”

 

TILING

 

 

 

 

 

 

 

 

 

 

mode.

 

IR CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER ON DELAY

HEAT STATUS

 

 

 

 

3 SEC.

 

 

 

 

 

 

 

DATE & TIME

 

 

 

 

 

 

 

 

 

 

 

 

POWER ON DELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCHEDULE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADVANCED OPTION RESET

 

 

 

 

 

 

 

 

 

 

 

 

“POWER ON DELAY” time is selectable between 0 and

 

 

 

 

+ -: ADJ

EXIT :RETURN MENU :EXIT MENU

 

:SEL SET :NEXT EXIT

:RETURN MENU :EXIT MENU

 

 

 

 

 

 

 

 

 

 

 

 

50 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADVANCED OPTION

 

 

DATE & TIME

 

 

 

 

 

 

 

 

 

 

 

IR CONTROL

 

 

YEAR

 

 

2004

 

 

 

 

 

 

 

 

MONTH

 

 

JANUARY

 

 

 

TILING

 

 

DAY

 

 

 

01

 

 

 

 

 

Adjusts the current date and time for internal clock.

DATE & TIME

HEAT STATUS

 

 

HOURTIME

 

 

00

 

 

 

 

 

POWER ON DELAY

 

MINUTE

 

 

00

: 00

 

 

 

DATE & TIME

 

 

DAYLIGHT SAVING

YES

/

NO

 

You should set this function when you use “SCHEDULE”.

 

ADVANCED OPTION RESET

 

CURRENT DATE

 

 

TIME

 

 

 

 

SCHEDULE

 

 

JAN. 01. 2004

00 : 00 : 00

 

 

 

 

 

 

 

 

 

 

 

:SEL SET :NEXT EXIT

:RETURN MENU :EXIT MENU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:SEL+ -:ADJ SET

:SET

EXIT

:RETURN MENU :EXIT MENU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADVANCED OPTION

 

 

SCHEDULE

 

 

 

 

 

 

 

 

 

Programs the monitor’s working schedule.

 

 

 

TODAY

2005.

4.

15

FRI

 

15:11

 

Schedule the power on and power off with hour and a day

 

IR CONTROL

 

1

ON

OFF

 

 

INPUT

 

SCHEDULE

TILING

 

2

08:30 17:15

 

RGN1

 

 

HEAT STATUS

 

 

 

of the week. Also sets the input port.

 

4

EVERY DAY

MON

 

TUE

 

DATE & TIME

 

 

 

 

POWER ON DELAY

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCHEDULE

 

5

WED

THU FRI

 

SAT

 

This OSD can’t remove except EXIT.

 

ADVANCED OPTION RESET

7

 

 

 

 

 

 

 

 

 

 

 

6

SUN

EVERY WEEK

 

 

 

 

 

 

:SEL SET :NEXT EXIT

:RETURN MENU :EXIT MENU

 

 

 

 

 

 

 

 

 

 

 

 

(see “NOTE 2” on page 27 for further information)

 

 

:SEL+ -:ADJ SET

:SET

EXIT

:RETURN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selecting ADVANCED OPTION reset allows you to reset

 

ADVANCED OPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

all OSD settings from ADVANCED OPTION settings,

 

IR CONTROL

 

 

ADVANCED OPTION RESET

 

 

 

 

except for DATE & TIME, and SCHEDULE.

ADVANCED

HEAT STATUS

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

TILING

 

 

 

 

 

 

 

 

 

 

 

 

 

Select “YES” and press “SET” button to restore the

OPTION RESET

POWER ON DELAY

 

 

YES

 

 

 

 

 

 

 

 

 

SCHEDULE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATE & TIME

 

 

 

 

 

 

 

 

 

 

 

 

factory preset data.

 

ADVANCED OPTION RESET

 

:SEL

EXIT :RETURN MENU :EXIT MENU

 

 

:SEL SET :NEXT EXIT

:RETURN MENU :EXIT MENU

 

 

 

 

 

 

 

 

 

 

 

 

Press “EXIT” button to cancel and then return the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

previous menu.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 