The following instructions should also be fully n oted. Incorrect handling may cause a fault, injury, electric
shock, etc.
(1) Transportation and installation
CAUTION
Transport the products correctly according to their weights.
Stacking in excess of the specified number of products is not allowed.
Do not carry the servo motor by the cables, shaft or encoder.
Do not hold the front cover to transport the ser vo amplifier. The servo amplifier may drop.
Install the servo amplifier in a load-bearing place in accordance with the Instruction Man ual.
Do not climb or stand on servo equipment. Do not put heavy objects on equipment.
The servo amplifier and servo motor must b e installed in the specified direction.
Leave specified clearances between the ser vo amplifier and control enclosure walls or o ther equipment.
Do not install or operate the servo amplifier and servo motor which has be en damaged or has any parts
missing.
Provide adequate protection to prevent screws and ot her conductive matter, oil and other combustible
matter from entering the servo amplifier and s ervo motor.
Do not drop or strike servo amplifier or servo m otor. Isolate from all impact loads.
When you keep or use it, please fulfill the f ollowing environmental conditions.
Conditions
Environment Servo amplifier Servo motor
[]0 to 55 (non-freezing) 0 to 40 (non-freezing)
In
operation [] 32 to 131 (non-freezing) 32 to 104 (non-freezing)
[ ] 20 to 65 (non-freezing) 15 to 70 (non-freezing)
Ambient
temperature In storage []4 to 149 (non-freezing) 5 to 158 (non-freezing)
In operation 90%RH or less (non-condensing) 80%RH or less (non-condensing)
Ambient
humidity In storage 90%RH or less (non-condensing)
Ambience Indoors (no direct sunlight) Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude Max. 1000m (3280 ft) above sea level
HC-KFS Series
HC-MFS Series
HC-UFS13 to 73
XY : 49
HC-SFS81
HC-SFS52 to 152
HC-SFS53 to 153
HC-RFS Series
HC-UFS 72 152
XY : 24.5
HC-SFS121 201
HC-SFS202 352
HC-SFS203 353
HC-UFS202 to 502
X : 24.5
Y : 49
HC-SFS301
HC-SFS502 to 702
X : 24.5
Y : 29.4
[m/s2] 5.9 or less
HA-LFS11K2 to 22K2 X : 11.7
Y : 29.4
HC-KFS Series
HC-MFS Series
HC-UFS 13 to 73
XY : 161
HC-SFS81
HC-SFS52 to 152
HC-SFS53 to 153
HC-RFS Series
HC-UFS 72 152
XY : 80
HC-SFS121 201
HC-SFS202 352
HC-SFS203 353
HC-UFS202 to 502
X : 80
Y : 161
HC-SFS301
HC-SFS502 to 702
X : 80
Y : 96
(Note)
Vibration
[ft/s2] 19.4 or less
HA-LFS11K2 to 22K2 X : 38
Y : 96
Note. Except the servo motor with reduction gear.