2 - 1
2. INSTALLATION
2. INSTALLATION
CAUTION
Stacking in excess of the limited number of pr oducts is not allowed.
Install the equipment on incombustible material. Installing them directly or close to
combustibles will lead to a fire.
Install the equipment in a load-bearing place in accordance with this Instruction
Manual.
Do not get on or put heavy load on the equipment to prevent injury.
Use the equipment within the specified environmental condit ion range. (For the
environmental conditions, refer to section 1 .3.)
Provide an adequate protection to prevent scre ws, metallic detritus and other
conductive matter or oil and other combustib le matter from entering the servo
amplifier.
Do not block the intake/exhaust ports of the servo amplifier. Otherwise, a fault may
occur.
Do not subject the servo amplifier to drop impact or shock lo ads as they are
precision equipment.
Do not install or operate a faulty servo amplifier.
When the product has been stored for an extended per iod of time, consult
Mitsubishi.
When treating the servo amplifier, be careful ab out the edged parts such as the
corners of the servo amplifier.
2.1 Environmental conditions
Environment Conditions
[]0 to 55 (non-freezing)
In
operation [] 32 to 131 (non-freezing)
[ ] 20 to 65 (non-freezing)
Ambient
temperature In storage []4 to 149 (non-freezing)
In operation
Ambient
humidity In storage 90%RH or less (non-condensing)
Ambience Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude Max. 1000m (3280 ft) above sea level
[m/s2] 5.9 [m/s2] or less