1 - 21
1. FUNCTIONS AND CONFIGURATION
1.7 Servo system with auxiliary equipment
WARNING
To prevent an electric shock, always connect the pr otective earth (PE) terminal
(terminal marked ) of the servo amplifier to the protec tive earth (PE) of the control
box.
(1) MR-J2S-100CP or less
(a) For 3-phase 200V to 230VAC or 1-phase 230VAC
(Note 2)
Power supply
Circuit breaker
(NFB) or fuse
Magnetic
contactor
(MC)
To CN2
To CN3
To CN1B
To CN1A
L1
L2
L21
L11
Protective earth (PE) terminal
Servo motor
Personal
computer
UVW
MR Configurator
(Servo configuration
software
MRZJW3-SETUP151E)
Servo amplifier
Regenerative option
D
P
C
CHARGE
Control circuit terminal block
(Note 1)
Encoder cable
(Note 1)
Power supply lead
L3
Power
factor
improving
reactor
(FR-BAL)
Options and auxiliary equipment
Circuit breaker
Magnetic contactor
MR Configurator
(Servo configuration software)
Regenerative option
Reference
Section 14.2.2
Section 14.2.2
Chapter 6
Section 14.1.1
Options and auxiliary equipment Reference
Cables
Manual pulse generator
External digital display
Section 14.2.1
Section 14.1.8
Section 14.1.7
Power factor improving reactor Section 14.2.3
Junction terminal block
Manual pulse generator
External digital display
Command device
Note 1. The HC-SFS, HC-RFS, HC-UFS 2000r/min series have cannon connectors.
2. A 1-phase 230VAC power supply may be used with the servo amplifier of MR-J2S-70CP or less.
For 1-phase 230VAC, connect the power supply to L1 L2 and leave L3 open. Refer to section 1.2 for the power supply
specification.