2 - 2
2. INSTALLATION
2.2 Installation direction and clearances
CAUTION
Do not hold the front cover to transport the servo am plifier. The servo amplifier
may drop.
The equipment must be installed in the specif ied direction. Otherwise, a fault may
occur.
Leave specified clearances between the s ervo amplifier and control box inside
walls or other equipment.
(1) Installation of one servo amplif ier
Control box Control box
10mm
(0.4 in.)
or more
10mm
(0.4 in.)
or more
40mm
(1.6 in.)
or more
40mm
(1.6 in.)
or more
Wiring clearance
70mm
(2.8 in.)
Servo amplifier
Up
Down