Indicators
The projector has three LED Indicators which shows the working condition of the projector.
The following offers solutions to possible problems. If a problem persists, turn the projector off and consult your dealer.
POWER indicator |
|
|
|
|
| COMPUTER | AUTO | MUTE | ||
|
|
|
|
| ||||||
|
|
|
|
| POSITION | |||||
LAMP indicator |
|
| LAMP | VOLUME SOURCE | ||||||
|
|
|
| |||||||
|
|
|
| |||||||
TEMP indicator |
|
|
| TEMP |
|
|
| VIDEO | MENU | ENTER |
|
|
|
|
|
|
POWER LAMP | TEMP CONDITION | Notes | |
Steady | Off |
| |
Off |
| ||
red |
|
|
|
|
| Lamp | The power button cannot be used to switch |
Steady | Blinking | Off | ON and OFF |
green | green |
| |
|
| The POWER is ON. (Normal condition) |
|
Steady | Steady | Off |
|
green | green |
|
|
ENGLISH
POWER LAMP | TEMP | |
Steady | Steady | Blinking |
green | green | red |
Steady | Off | Blinking |
red |
| red |
CONDITION | POSSIBLE SOLUTIONS |
Unusual temperature | • Remove the object from the ventilation |
• The ventilation slits or air filter is clogged with | |
dust or debris. | slits. |
• The room temperature is too high. | • Relocate the projector to a cooler place. |
• The filter is dirty. | • Clean the filter. |
|
|
|
|
|
| The protection circuit is working or the lamp is in an |
|
|
|
|
|
| |
Steady | Blinking Off | abnormal condition. | ||||
red | green | (The indicators operate as shown on the left at the time of | ||||
|
|
|
|
|
| |
|
|
|
|
|
| abnormal condision.) |
Lamp duration warning. (Lightning duration total
Steady Blinking Off about 1, 500 hours*.When the POWER is ON.)
green green/red
Steady | Blinking | Off | Lamp duration warning. (Lightning duration total | |
about 1, 500 hours*.When the POWER is OFF.) | ||||
red | red |
|
•Wait until the LAMP indicator is turned off, then press the POWER button.
•If the above operation is not effective, replace the lamp.
Replace the lamp.
Exchange with a new lamp if the same problem recurs.
Steady | Steady | Off | Lamp duration warning. (Lightning duration total |
|
about 2,000 hours*.) |
| |||
red | red |
|
| |
|
|
| The lamp cover is not closed. | Close the cover correctly. |
Blinking | Off | Off |
|
|
green/red |
|
|
|
|
| Steady | Steady | Abnormal. | Contact your dealer. |
|
|
| ||
Blinking | or | or |
|
|
|
|
|
| |
green/red |
|
|
|
|
| Blinking | Blinking |
|
|
*) When LAMP MODE of the INSTALLATION menu is set to STANDARD. When it is set to LOW, the duration will be extended.