7

Hang assembled fan from the mounting bracket installed to ceiling in previous step. Make sure the fan is hanging straight. Rotate fan until the tab on the Mounting bracket engages the slot on the Downrod Ball. This must be done to prevent the fan body from rotating when the blades are in motion.

8

Canadian mounting only

Safety

Cable

 

Lag Screw

Lag Screw

Safety Cable

Washer

Lock Washer

For Canadian installation in both flush and down- rod mode the safety cable must be installed into the house structure beams using the 3” lag screws provided. Make sure that when the safety cable is fully extended the leadwires are longer than the cable and no stress is placed on the leadwires.

9

Make sure the studs protruding from the bottom of the Mounting bracket are installed with threads all the way through the bracket.

10

House

Black

White

Ground

Fan

Blue

Black

White

Green

11

12

Connect black and blue wire from fan to Black or (Hot) wire from house. Connect White wire from Fan to White (Neutral) wire from house. Connect Ground leads from mounting bracket and downrod to Ground lead from house. Refer to Safety Tips section of manual.

13

Next lift the canopy disk and install knurled nuts as shown. Tighten the knurled nuts securely. The canopy should adjust for any irregularity in the ceiling or Outlet box.

16

Install switch cap to fan using the 3 screws provided. Tighten securely.

Make wire connections to power source using wire nuts provided. Make sure that no filiments are outside of the wirenut. After making the wire connections, the wires should be spread apart with the grounded con- ductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

14

Place blade holders onto blades aligning holes in blade holder with holes in blade. Make sure that the side of the blade you select is facing downward. Install 3 screws and fiber wash- ers to back side of blade as shown. Tighten screws securely. Repeat this process 4 more times until all blades are assembled.

17 Flush Mount Installation

Pass leadwires and safety cable through the canopy.

Canopy disk

Lift canopy allowing the 2 studs to protrude through the canopy.

15

Install blades to motor using the 10 motor screws provided. Tighten screws securely.

18

Remove side covers from canopy exposing 4 holes. 2 closed holes and 2 open “L” shape holes.

Page 3
Image 3
Monte Carlo Fan Company 5CO52 installation instructions Flush Mount Installation