Insert downrod into motor yoke. Next, insert clevis pin through yoke and downrod.

8

Secure with cotter pin.

9

Tighten both yoke set screws to fur- ther secure downrod.

10

Remove screws from stabilizer plate on bottom of fan motor.

13Safety cable installation

Safety Cable

Lag Screw

safety cable

washer

3” Manual backgroundlag lock screw washer

For Canadian installation and for USA fan and light kit combinations over 35 lbs, in both flush and downrod mode the safety cable must be installed into the house structure beams using the 3” lag screws,washers, and lock washers. provided. Make sure that when the safety cable is fully extended the leadwires are longer than the cable and no stress is placed on the lead- wires.

11

Remove stabilizer plate you will not need this plate.

14

Make wire connections to power source using wire nuts provided. Make sure that no filiments are outside of the wirenut. After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment- grounding conductor on one side of the out- let box and ungrounded conductor on the other side of the outlet box.

12

Carefully lift fan assembly onto mounting bracket. Rotate fan so that the notch on the ball engages the ridge in the mounting bracket. This will allow hands-free wiring.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

House

 

 

Fan

 

 

 

 

 

15

 

 

 

 

Black

 

 

 

 

Black

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blue

 

 

 

 

 

White

 

 

 

 

 

White

 

 

 

 

 

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Green(downrod)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Green(Bracket)

 

For pullchain controls, follow diagram above. Make sure that all exposed wiring is secured inside wire nuts. Note: Wires from house may vary in color and may not include ground wire. After wiring is conplete, gently push wires into junction box with wire nuts pointing upward. Refer to point 3 of safety tips.

16

Fan Switch

Light Switch

Wall

Control

For control of fan and optional light from wall location, follow diagram above. NOTE: A profes- sional electrician is recommended for this type of installation.

17

Raise the canopy up and align the two holes in the canopy with the two holes in the hanger bracket. Secure with two screws provided.

18

Install 3 screws and washers per blade and tighten securely. Repeat for all 5 blades. The blades will have a label showing this side up on each blade.