WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70- 1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

5. Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

7. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.

8. To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support.

9. (Mounting must support at least 35 lbs.)

10. Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.

11. Attach the mounting bracket using only the hardware supplied with the outlet box.

12. To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

13. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

14. NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equip- ment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American

15. Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

 

 

Phillips Screwdriver

TOOLS REQUIRED

Pliers

 

1

Wire Cutters

 

2

 

 

 

Unpack and inspect fan carefully to

 

Before you begin installing the fan, Switch power off

 

 

 

 

 

 

to prevent power from being switched on accidentally.

 

 

be certain all contents are included.

 

at Service panel and lock service disconnecting means

 

 

 

When the service disconnecting means cannot be

 

 

(See exploded view parts lists.)

 

locked, securely fasten a prominent warning device,

 

 

 

such as a tag, to the service panel.

 

 

4

 

 

5

 

 

 

 

 

 

 

 

Install mounting brackets to outlet

 

Feed motor lead wires through downrod/canopy

 

 

 

 

 

 

assembly and insert downrod into motor yoke.

 

 

box in ceiling using the screws and

 

Next, insert clevis pin through yoke and down-

 

 

washers provided with the outlet

 

rod and secure with cotter pin. (see Inset)

 

 

 

Tighen both yoke set screws to further secure

 

 

box.

 

downrod.

 

Step Ladder

3

Before installing this fan make sure the outlet box is properly installed to the house structure. To reduce the risk of fire, electric shock, or per- sonal injury, mount to outlet box or supporting system acceptable for fan support.

(Mounting must support at least 35 lbs.)

6

Carefully lift fan assembly onto mounting bracket. Rotate fan so that the notch on the ball engages the ridge in the mount- ing bracket. This will allow hands-free wiring.

Page 2
Image 2
Monte Carlo Fan Company 5PR52 owner manual Mounting must support at least 35 lbs, Unpack and inspect fan carefully to, Box

5PR52 specifications

The Monte Carlo Fan Company 5PR52 is a ceiling fan that seamlessly combines style, performance, and efficiency. Its modern design and reliable functionality make it a popular choice among homeowners looking for both aesthetics and practicality in their indoor spaces.

One of the standout features of the 5PR52 is its 52-inch blade span, which provides ample airflow for medium to large-sized rooms. The fan boasts five blades crafted from high-quality materials, ensuring durability while promoting energy efficiency. The blades come in various finishes, allowing homeowners to choose one that complements their existing décor.

The 5PR52 is powered by a robust motor that is designed to deliver superior performance. This energy-efficient motor operates quietly, making it an ideal choice for bedrooms, living rooms, or any space where noise disruption is a concern. The fan's reverse function allows it to effectively circulate air in both the summer and winter months, ensuring comfortable temperatures year-round.

Another notable aspect of the Monte Carlo 5PR52 is its stylish design. With clean lines and a sleek profile, this ceiling fan fits seamlessly into various interior design styles, from contemporary to traditional. The fan is available in multiple finishes, including a matte black, oil-rubbed bronze, and brushed nickel, enabling homeowners to select the option that best suits their aesthetic preferences.

Additionally, Monte Carlo has integrated advanced technologies into the 5PR52 model, such as the ability to control the fan via a remote control or wall switch, depending on user preference. Many versions of the 5PR52 are also compatible with smart home systems, allowing for voice activation and integration into existing smart home ecosystems.

Installation is straightforward, making it accessible for DIY enthusiasts. The fan comes with a comprehensive manual that guides users through the installation process. Furthermore, the aerodynamic blade design enhances energy efficiency, potentially leading to lower electricity bills.

In summary, the Monte Carlo Fan Company 5PR52 ceiling fan stands out for its impressive blend of design and functionality. With features like a powerful motor, quiet operation, and stylish aesthetic choices, this fan is well-suited for those seeking a reliable and attractive cooling solution in their home. Its commitment to energy efficiency and modern technology further solidifies it as a top choice among ceiling fans on the market today.