Changing the belt

8607 Upright ib 73303 29/07/2003 11:00 Page 6

Changing the belt

If the power brush stops rotating it is likely that the drive belt has snapped (usually because the brush has been stalled). A spare belt is supplied. Replacement belts can also be obtained from Morphy Richards or a Service Agent.

Removing the floor nozzle cover GH

1Disconnect the cleaner from the mains supply.

2Place the cleaner upside down in the flat position.

3Use a cross-head screwdriver to remove the two screws at the front and the central screw under the height adjustment mechanism G.

4Turn the cleaner over and remove the carpet height adjustment knob .

5Remove the two screws at the rear and

lift the rear of the cover over the handle release button and unclip the cover from the front of the floor nozzle H.

Replacing the belt IJ

6If the belt has broken, ensure all pieces are removed.

7Lift off the belt cover Ï.

8Grasp the brush bar Ì at both ends and lift straight up.

9Place one end of the new belt over the metal motor shaft pin and the other around the pulley end of the brush J.

10Align brush end plates with their guide slots and push the brush bar down into place.

11Re-fit the belt cover.

12Re-fit the floor nozzle cover. Push the carpet height adjustment knob back on.

13Replace the two screws on the top of the floor nozzle cover and the three screws underneath the floor nozzle - do not overtighten.