HOOK-UP INFORMATION

HOOK-UP INFORMATION

1.1Heater model MH24T and MH24TS are packaged completely assembled. Propane cylinders are not included with heater models.

1.2Remove heater assembly from carton.

1.3Place the slots of the black collar mounting bracket assembly onto the collar of the bulk tank (see Fig. 1)

CAUTION:

BE SURE THE LOCKING KNOB ON THE COLLAR MOUNT- ING BRACKET ASSEMBLY IS OUTSIDE THE COLLAR ON THE BULK TANK. Tighten the black knob against collar of tank.

1.4

mounting bracket assembly with the three #6-32x1/2 screws and #6-32 Keps hex nuts. Be sure screws and nuts are secure and tight.

1.5Make sure tank valve is in “OFF” position (clockwise).

REFLECTOR

HOSE ASSEMBLY

REGULATOR

KNOB

1.6Make sure regulator knob is in “OFF” position by turning knob clockwise to off.

1.7

turning counterclockwise; then with a 7/8” open end wrench tighten the POL fitting, hard.

1.8Always connect the heater to bulk tank in the outdoors or in a well ventilated area. NEVER connect heater to bulk tank near an open flame.

1.9Use only LP-gas cylinders constructed for use with propane only

LP-gas cylinders of the U.S. Department of Transportation (DOT Spec. 39).

1.10Read pages 3 and 4 before lighting heater.

MODEL MH24T WARNING

Never touch heater while in operation to avoid injury. Move heater by grasping the propane cylinder carefully.

TIGHTEN

 

LOCKING

SPARKLITE IGNITER

KNOB

 

POL NUT

 

LP CYLINDER

SAFETY

 

SHUT OFF VALVE

MODEL MH24T

 

COLLAR

 

MOUNTING BRACKET

TANK VALVE

 

Figure 1

MODEL MH24TS

Mr. Heater Gas-Fired Infra-Red Portable Heater

3

Operating Instructions and Owner’s Manual

Page 3
Image 3
Mr. Heater operating instructions Hook-Upinformation, MODEL MH24TS