INSPECTION PROCEDURE continued

INSPECTION PROCEDURE continued

5.Locate the control valve at the operator’s position of the log splitter and look at the control valve end cap (opposite end from the control handle). See Figure 2.

End Cap

21 to 33 Ton

Control Valve

 

 

 

 

 

 

 

 

 

8 Ton

 

 

 

 

 

 

 

 

Control Valve

End Cap

FIGURE 2

6.If the valve has the name “ENERGY” on the end cap, as shown in Figure 3, the valve must be tested. Proceed to the “TEST PROCEDURE” section on Page 3.

If the end cap on the control valve does not have the name “ENERGY” on it, your log splitter is not affected by this recall. You should stop here.

FIGURE 3

If you have any questions related to this Inspection and Test Procedure, call

MTD Customer Service toll free at

1-888-848-6038

Monday through Friday 8:00 AM and 5:00 PM Eastern Time

Saturday

10:00 AM to 3:00 PM Eastern Time

2 of 3

Form No. 769-05565