Chapter 2 – AT Commands

Command:

+GCI

Country/Region of Installation

Description:

 

This extended syntax command selects and indicates the region/country of installation for

 

 

the modem. The parameter selects the settings for any operational parameters that need

 

 

to be adjusted for national regulations or telephone networks.

 

 

Syntax: +GCI=<region_code>Defined Values: <region_code>Example: Euro/Nam = B5.

 

 

For a list of regions/countries approvals and codes, see the Multi-Tech Web site at:

 

 

http://www.multitech.com/PRODUCTS/Info/approvals

Default:

 

If the modem is specified for use in only one country, the country code is the default.

 

 

Otherwise, the default is defined by the OEM. The factory default is B5.

Report Commands:

+GCI?

Reports current or selected values.

 

 

+GCI=?

Reports supported range of parameter values.

Command:

+MS= Modulation Selection

 

Values & Default:

See description.

 

 

Description:

 

This extended-format command selects modulation and, optionally, enables or disables

 

 

automode, specifies the lowest and highest connection rates, selects µ-Law or A-Law

 

 

codec type, and specifies the highest transmit rate using one to five subparameters.

 

 

The command format is:

 

 

 

+MS=[+MS=[<carrier>[,<automode>[,<min_TX_rate>[,<max_TX_rate>[,min_RX_rate>[,<max_RX_rate>]]]]]]

 

 

Subparameters that are not entered retain their current value. Commas separate optional

 

 

subparameters and should be inserted to skip a subparameter. Example: +MS=,0,<CR>

 

 

disables automode and keeps all other settings at their current values.

Subparameters:

 

mod A decimal number that specifies the preferred modulation (automode enabled) or

 

 

the modulation to use in originating or answering a connection (auto-mode disabled).

 

 

+MS Command Supported Rates

 

 

Modulation

<carrier>

Possible (<min_rx_rate>,<max_rx_rate>,(<min_tx_rate>), and

 

 

 

 

 

<max_tx_rate>) Rates (bps)

 

 

Bell 103

B103

300

 

 

Bell 212

B212

1200 Rx/75 Tx or 75 Rx/1200 Tx

 

 

V.21

 

V21

300

 

 

V.22

 

V22

1200

 

 

V.22 bis

V22B

2400 or 1200

 

 

V.23

 

V23C

1200

 

 

V.32

 

V32

9600 or 4800

 

 

V.32 bis

V32B

14400, 12000, 9600, 7200, or 4800

 

 

V.34

 

V34

33600, 31200, 28800, 26400, 24000, 21600, 19200, 16800, 14400,

 

 

 

 

 

12000, 9600, 7200, 4800, or 2400

 

 

V.90

 

V90

56000, 54667, 53333, 52000, 50667, 49333, 48000, 46667, 45333,

 

 

 

 

 

44000, 42667, 41333, 40000, 38667, 37333, 36000, 34667, 33333,

 

 

V.92 downstream V92

32000, 30667, 29333, 28000

 

 

same as V.90 above

 

 

V.92 upstream

V92

48000, 46667, 45333, 44000, 42667, 41333, 40000, 38667, 37333,

 

 

 

 

 

36000, 34667, 33333, 32000, 30667, 29333, 28000, 26667, 25333,

24000

Note: Some <carrier> values may not be supported by certain model models.

automode An optional numeric value that enables or disables automatic modulation negotiation using V.8bis/V.8 or V.32bis Annex A. The options are:

0 = Disables automode

1 = Enables automode (default)

<min_rx_rate> and <max_rx_rate>

Numeric values which specify the lowest (<min_rx_rate>) and highest

(<max_rx_rate>) rate at which the modem may establish a receive connection. May be used to condition distinct limits for the receive direction as distinct from the transmit direction. Values for this subparameter are decimal encoded, in units of bit/s. The possible values for each modulation are listed in the table above. Actual values will be limited to possible values corresponding to the entered <carrier> and fall-back <carrier> as determined during operation. (Default = lowest (<min_rx_rate>) and highest (<max_rx_rate>) rate supported by the selected carrier.)

<min_tx_rate> and <max_tx_rate>

Numeric values which specify the lowest (<min_tx_rate>) and highest

(<max_tx_rate>) rate at which the modem may establish a transmit connection. Non- zero values for this subparameter are decimal encoded, in units of bit/s. The possible values for each modulation are listed in the table above. Actual values will be limited to possible values corresponding to the entered <carrier> and fall-back <carrier> as determined during operation. (Default = lowest (<min_tx_rate>) and highest (<max_tx_rate>) rate supported by the selected carrier.)

Multi-Tech Systems, Inc. AT Commands Reference Guide (S000273G)

14

Page 14
Image 14
Multi-Tech Systems MT5600BA-V92 manual Country/Region of Installation, Command +MS= Modulation Selection, Values & Default

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.