This chapter describes how to use callback security with your modem. Callback security protects your network from unauthorized access and helps control long-distance costs. When callback security is enabled, all callers are requested to enter a password. If a valid password is received, the modem hangs up and returns the call by dialing a phone number that is stored with the password. The person being called back must then enter the password a second time to establish a connection.

Up to 30 callback passwords and dialing strings can be stored in the modem. Each dialing string can be up to 34 or 35 characters long and can contain commands as well as phone numbers. For mobile callers, the dialing string can be programmed to allow the caller to bypass the stored callback number by entering a temporary callback number, to enter an extension at the callback number, or to make a direct connection without callback.

For local security, the passwords and dialing strings that are stored in the modem are protected from tampering by a setup password, which you should change when you set up the modem. You can further protect the modem against tampering by disabling its ability to respond to most AT commands. To check for attempted break-ins, you can request the modem to display the number of failed password attempts.

Your modem was shipped with a default setup password (MTSMODEM). The same password is used for both callback security and remote configuration (Chapter 4). Because anyone who has access to this guide has access to the default password, you should change the password during your initial setup.

Changing the Setup Password

1.Open a data communications program such as HyperTerminal.

2.In the terminal window, type AT#SMTSMODEM (or AT#Sxxxxxxxx if you have replaced the MTSMODEM password with xxxxxxxx). Press ENTER. The modem responds with OK if the setup password is correct and ERROR if it is wrong.

3.To change the password, type AT#S=xxxxxxxx, where xxxxxxxx stands for the password, and then press

ENTER. The password can include any keyboard character, and can be up to eight characters long. The modem responds with OK.

4.The new password is saved automatically. You can now either enter more AT commands or exit the data communications program. The next time you wish to set up the modem, you must use the new password.

CAUTION: Passwords are case-sensitive. The next time you enter the password, it must be in the same case as you set it up.

Turning Callback Security On and Off

Callback security must be turned on to enter many callback security commands.

1.Open a data communications program such as HyperTerminal.

2.In the terminal window, type AT#Sxxxxxxxx, where xxxxxxxx is your password. Press ENTER. The modem responds with OK if the setup password is correct and ERROR if it is wrong.

3.Type one of the following commands:

To turn off callback security: Type AT#CBS0 and press ENTER. Callers no longer need a password to connect to the modem, the modem is unable to call them back, and the stored dialing command locations 0–3 become available.

To turn on both local and remote callback security: Type AT#CBS1. Press ENTER. With local security turned on, you must enter the setup password before you can enter any AT command except the AT, ATIn, and AT#Sxxxxxxxx commands. For a description of remote callback security, see the following paragraph.

To turn on remote callback security only: Type AT#CBS2 and press ENTER. With remote callback security turned on, each caller is asked to enter a password, is called back, and then is asked to enter the password again before a connection can be made. Also, dialing command locations 0–3 for use with the DS=y dialing command are replaced by callback dialing command locations 0–29.

To temporarily disable callback security if the modem is set to #CBS1 or #CBS2 (for instance, to call another modem): Type AT#CBS3 and press ENTER. The modem returns to its original setting when you issue the hangup command (+++ATH) or the modem is reset. Note that if a remote modem breaks the connection, callback security remains disabled.

16

Multi-Tech Systems, Inc. MT9234ZBA-Series User Guide (S000387A)

Page 16
Image 16
Multi-Tech Systems MT9234ZBA-V manual Changing the Setup Password, Turning Callback Security On and Off

MT9234ZBA-V, MT9234ZBA specifications

Multi-Tech Systems has long been a trusted name in the field of communication technology, and its MT9234ZBA and MT9234ZBA-V modem products exemplify the company's commitment to delivering robust and reliable connectivity solutions. These modems are ideal for a range of applications, including telephony, data communication, and remote monitoring, making them a versatile choice for both personal and professional use.

One of the standout features of the MT9234ZBA and MT9234ZBA-V is their high-speed data transmission capabilities. Both models support data rates of up to 56 Kbps, ensuring efficient and swift data transfer for various applications. This allows users to experience minimal latency during downloads and uploads, appealing to those who depend on timely and reliable data delivery.

These modems utilize advanced technologies, such as V.92 and V.90 protocols, which enable users to benefit from features like quick connect, thereby reducing the time it takes to establish a connection. Additionally, the modems support both analog and digital lines, making them adaptable for different environments and infrastructures.

Another notable characteristic of the MT9234ZBA and MT9234ZBA-V modems is their compatibility with a wide range of operating systems, including various versions of Windows, Linux, and Mac OS. This cross-platform support ensures that users can easily integrate these modems into their existing software environments without encountering significant compatibility issues.

The design and construction of these modems are also worth mentioning. They are compact and lightweight, making them easy to install and reposition as needed. Their robust construction ensures longevity, which is crucial for users in environments where durability is paramount.

For those concerned about security, Multi-Tech Systems has integrated multiple security features within these modems. This includes support for encryption protocols, ensuring that data transmitted over the modem remains secure and protected from unauthorized access.

In conclusion, the MT9234ZBA and MT9234ZBA-V by Multi-Tech Systems represent an excellent choice for anyone in need of reliable and high-speed modem solutions. With their advanced features, compatibility with various operating systems, and emphasis on security, these modems stand out in the crowded telecommunications market. Whether for home use or in a professional setting, the MT9234ZBA and MT9234ZBA-V offer robust solutions for modern communication needs.