DCA70USI

MQ POWER Series Generator

Specifications

Generator Specifications

Design

Revolving field, self-ventilated

Drip-proof, single bearing

 

Armature Connection

Star with Neutral

 

Zig Zag

Phase

3

 

Single

Standby Output

62 KW (77 KVA)

 

44 KW

Prime Output

56 KW (70 KVA)

 

40 KW

3Ø Voltage (L-L/L-N)

208Y/120, 220Y/127,

 

N/A

Voltage Selector Switch at 3Ø 240/139

240Y/139

 

 

 

3Ø Voltage (L-L/L-N)

416Y/240, 440Y/254,

 

N/A

Voltage Selector Switch at 3Ø 480/277

480Y/277

 

 

 

1Ø Voltage (L-L/L-N)

N/A

 

240/120

(Voltage Selector Switch at 1Ø 240/120)

 

 

 

 

Power Factor

0.8

 

1.0

Voltage Regulation (No load to full load)

±0.5%

 

Generator RPM

1800

 

Frequency

60 Hz

 

No. of Poles

4

 

 

Excitation

Brushless with AVR

Frequency

60 Hz

 

Frequency Regulation:

Isochronous under varying loads from

No Load to Full Load

no load to 100% rated load

Frequency Regulation: Steady State

±0.25% of mean value for constant loads

from no load to full load.

 

Insulation

Class H

 

Sound Level dB(A) Full load at 23 feet

68

 

 

Engine Specifications

Make / Model

Isuzu / BJ-4JJ1X

Emissions

EPA Interim Tier 3 Certified

Starting System

Electric

Design

4-cycle, water cooled,

direct injection, turbocharged

 

Displacement

183.0 in3 (2999 cc)

No. cylinders

4

Bore x Stroke (mm)

95.4 x 104.9

Gross Engine Power Output

97.9 bhp (50 kW)

BMEP

204 psi (1409 kPa)

Piston Speed

1237 ft./min. (6.29 m/s)

Compression Ratio

17.5:1

Engine Speed

1800 rpm

Overspeed Limit

2100 rpm

Oil Capacity

3.96 gallons (15 liters)

Battery

12V 72Ah x 1

Fuel System

Recommended Fuel

ASTM-D975-No.1 & No.2-D

Maximum Fuel Flow (per hour)

16 gallons (61 liters)

 

Maximum Inlet Restriction (Hg)

5.9 in. (150 mm)

 

Fuel Tank Capacity

103 gallons (390 liters)

Fuel Consumption

gph

 

lph

At full load

4.1

 

15.4

At 3/4 load

3.1

 

11.9

At 1/2 load

2.1

 

8.1

At 1/4 load

1.3

 

4.8

Cooling System

Fan Load

0.4 hp (0.3 kW)

Coolant Capacity (with radiator)

3.57 gallons (13.5 liters)

Coolant Flow Rate (per minute)

15.4 gallons (58.5 liters)

Heat Rejection to Coolant (per minute)

2260 Btu (2.38 MJ)

Heat Rejection to Room (per minute)

578 Btu (0.61 MJ)

Maximum Coolant Friction Head

6.1 psi (42 kPa)

Maximum Coolant Static Head

21 feet (6.4 meters)

Ambient Temperature Rating

104°F (40°C)

Air

Combustion Air

138 cfm

(3.9 m3/min)

Maximum Air Cleaner Restriction

25 in. H2O (6.25 kPa)

Alternator Cooling Air

526 cfm (14.9 m3/min)

Radiator Cooling Air

2009 cfm

(56.9 m3/min)

Exhaust System

Gas Flow (full load)

332 cfm (9.4 m3/min)

Gas Temperature

932°F (500°C)

Maximum Back Pressure

53.2 in. H2O (13.3 kPa)

Amperage

Rated Voltage

Maximum Amps

1Ø 120 Volt

155.4 Amps (4 wire)

168A x 2 (Zigzag)

 

1Ø 240 Volt

77.8 Amps (4 wire)

168A (Zigzag)

 

3Ø 240 Volt

168 Amps

3Ø 480 Volt

84 Amps

Main Line Circuit Breaker Rating

175 Amps

Over Current Relay Trip Set Point

84 Amps

480V Mode Only

 

Warranty*

Isuzu Engine

12 months from date of purchase with unlimited hours or 24 months from date of purchase with 2000 hours (whichever comes first).

Generator

24 months from date of purchase or 2000 hours (whichever occurs first).

Trailer

12 months excluding normal wear items.

*Refer to the express written, one-year limited warranty sheet for additional information.

NOTICE

Generator is not intended for use in enclosed areas or where free flow of air is restricted.

Backfeed to a utility system can cause electrocution, shock and/ or property damage. DO NOT connect to any building’s electrical system except through an approved device.

Specifications are subject to change without notice.

DCA70USi — MQ POWER series generator — Rev. #8 (04/17/12)

Page 2
Image 2