OPERATION

Figure 13. Choke Lever (Open)

8.Before the pump is placed into operation, run the engine for severalminutes.

9.Check for fuel leaks and noises that would be associated with a loose component.Check for leaks between pump and engine. If water is leaking between the pump and engine housing, the seal inside the pump may be worn or damaged. Continued operation of the pump is not recommended. Further usage of the pump under these conditions may cause severe water damage to engine.

10.To begin pumping, place the throttle lever (Figure 14) in the RUN position. If water is not flowing out of the discharge port, turn off the engine and check for and clear any obstructions within the suction hose.

 CAUTION — Maximum Engine Speed CAUTION — Maximum Engine Speed

ALWAYS run engine at full speed while pumping.

STOPPINGTHE ENGINE

Normal Shutdown

1.Move the throttle lever to the IDLE position (Figure 15) and run the engine for three minutes at low speed.

Figure 15. Throttle Lever (Idle)

2.After the engine cools, turn the engine ON/OFF switch to the OFF position (Figure 16).

Figure 14. Throttle Lever (Run)

STOPPINGTHE ENGINEWARNING — High Pressure

Water must always be flowing through the pump casing while theengineisrunning.Lossofflowmaybetheresultofalossof prime, restricted water flow or a dead-head situation. Please note that in such a condition, water in the pump can reach temperaturesof150-200°Fin15to20minutes.Thiscancause serious burns if this hot water comes into contact with unprotected skin. Before touching or opening the fill plug or drainplug,firstturnofftheengineandallowthepumpcasingto cooltothetouch,andthenopenthepumpcarefully.Becautious of any built up water pressure.

Figure 16. Engine ON/OFF Switch (OFF)

3. Place the fuel shut-off lever (Figure 17) in the OFF position.

Figure 17. Fuel Valve Lever (OFF)

Emergency Showdown

1.Move the throttle lever quickly to the IDLE position, and place the engine ON/OFF switch in the OFF position.