Image 2
Generator Specifications

TLG12SPX

WhisperWattTM Generator

Generator Specifications

Type

2-Pole, Revolving field, Self-ventilated,

Drip-proof, Single bearing

 

Excitation

Brushless with AVR

Number of Leads

4 Leads

Frequency

60 Hz

Insulation

Class F

Generator RPM

3600

Power Factor

1.0

Armature Connection

Series

Voltage Regulation (no load to full load)

±0.5%

Sound Level dB(A) Full load 23 ft.

68

 

 

Engine Specifications

Make

Kubota

Model

D902

Emissions

EPA Tier 4 Certified

 

 

Design

3 cylinder, 4-cycle, water cooled,

Swirl Chamber

 

Displacement

898 cc

Bore

2.83 in. (72 mm)

Stroke

2.89 in. (73.6 mm)

 

 

SAE Gross Horsepower

24.8 hp

 

 

Starting System

Electric

Battery

12V 45 Ah x 1

Oil Capacity

0.95 gal (3.6 L)

Coolant Capacity

0.92 gal (3.5 L)

 

 

 

Fuel System

 

 

 

 

 

 

Fuel Tank Capacity

 

 

13.5 gal (51.1 L)

 

 

 

Fuel Consumption

 

 

 

Diesel Fuel At % of Load

 

 

gal/hr (L/hr)

 

 

 

100%

 

1.4 (5.2)

 

 

 

 

75%

 

1.1 (4.4)

 

 

 

 

50%

 

1.0 (3.8)

 

 

 

 

25%

 

0.8 (3.1)

 

 

 

 

 

 

 

 

 

 

Weights and Measurements

 

 

 

 

 

Housing (mm)

A

 

B

 

C

56 in. (1422)

 

34 in. (863)

 

28 in. (711)

 

 

 

 

 

 

 

 

 

 

 

Appx. Dry Weight

 

 

858 lbs (389 kg)

 

 

 

 

 

 

 

 

 

Appx. Wet Weight

 

 

964 lbs (437 kg)

 

 

 

 

 

 

 

 

 

 

 

Max. Lifting

 

1600 lbs (735 kg)

 

 

Point Capacity

 

 

 

 

 

 

 

 

 

 

Warranty*
Top View

Kubota Engine

 

24 months or 2000 hours from date of purchase (whichever occurs first).

Generator

24 months or 2000 hours from date of purchase (whichever occurs first).

*Refer to the express written, one-year limited warranty sheet for additional information.

Trailer

12 months excluding normal wear items.

Generator is not intended for use in enclosed areas or where free flow of air is restricted.

Backfeed to a utility system can cause electrocution and/or property damage. Do not connect to any building’s electrical system except through an approved device.

Specifications are subject to change without notice.

Your MQ Power dealer is:

© COPYRIGHT 2008, MQ POWER Rev 5 (09-08) TLG12SPX4

MQ POWER

POST OFFICE BOX 6254 CARSON, CA 90749

310-537-3700800-421-1244 FAX: 310-632-2656

E-MAIL: mqpower@multiquip.comWEBSITE: www.mqpower.com
Page 2
Image 2
Multiquip TLG12SPX WhisperWattTM Generator, Mq Power, Warranty, Generator Specifications, Engine Specifications, Top View