Murphy How to Order, 45PEBP - 4 - S- 100 - EX, 45PE Series Typical Wiring Diagram, FWMurphy

Models: 45PE Series

1 2
Download 2 pages 57.15 Kb
Page 2
Image 2
How to Order

How to Order

Specify model number. NOTE: No designator is required for Standard configurations.

List options in alphabetical order (A to Z). Place a dash (–) between each option. See example below.

45PEBP – 4 – S– 100 – EX

Base Model

45PE 45PEE

45PEF 45PEBPE 45PEBP

BP Voltage (This feature is NOT cover by CSA or the CE mark)

Blank= 120 VAC 2 = 12 VDC

3 = 24 VAC

4 = 24 VDC

Bourdon Tube/Socket

A = Bronze/Brass (/std. < =1,000 psi)

R = Stainless Steel/Steel (std. >= 1,500 psi)

S = Stainless Steel/Stainless Steel

P = K Monel/Monel 400

Range

Code

Vacuum/psi

kPa/MPa

bar

30HV60H

30” Hg/Vac - 60” Hg/Press.

-101 kPa–203 kPa

-1.01–2.03

30V

30”

vac -

0 psi

-101 kPa - 0 kPa

-1.01 - 0

30V15

30”

vac -

15 psi

-101 kPa - 103 kPa

-1.01 - 1.03

30V30

30”

vac -

30 ps

-101 kPa - 207 kPa

-1.01 - 2.07

30V100

30”

vac -

100 psi

-101 kPa - 689 kPa

-1.01 - 6.89

30V200

30” vac -

200 psi

-101 kPa - 1.38 MPa

-1.01 - 13.79

30V300

30” vac -

300 psi

-101 kPa - 2.03 MPa

-1.01 - 20.68

15

15 psi

 

0

- 103 kPa

0

- 1.03

30

0

- 30 psi

 

0

- 207 kPa

0

- 2.06

60

0

- 60 psi

 

0

- 414 kPa

0

- 4.13

100

0

- 100 psi

0

- 689 kPa

0

- 6.89

160

0

- 160 psi

0

- 1.10 MPa

0

- 11.03

200

0

- 200 psi

0

- 1.38 MPa

0

- 13.78

300

0

- 300 psi

0

- 2.07 MPa

0

- 20.68

400

0

- 400 psi

0

- 2.76 MPa

0

- 27.57

600

0

- 600 psi

0

- 4.14 MPa

0

- 41.36

1000

0

- 1000 psi

0

- 6.89 MPa

0

- 68.95

1500

0

- 1500 psi

0

- 10.34 MPa

0

- 103.42

2000

0

- 2000 psi

0

- 13.79 MPa

0

- 137.89

3000

0

- 3000 psi

0

- 20.68 MPa

0

- 206.84

5000

0

- 5000 psi

0

- 34.48 MPa

0

- 344.73

10000

0

- 10,000 psi

0

- 68.95 MPa

0

- 689.47

20000

0

- 20,000 psi

0

- 137.90 MPa

0

- 1378.94

Options (NOTE: Not all options available for every model.)

BC = Back Connected Bourdon Tube (is not CSA certified)

CC= Conduit Connection (is not CSA certified)

ES = Environmentally Sealed, 45PEF only (is not CSA certified) EX = Explosion-proof (hazardous areas certified up to 5000 psig) EL = (EXLC) Explosion-Proof Less Case

LC = Less Case (is not CSA certified)

OS = Oil Sealed, 45PEF only (is not CSA certified)

P4 = (PT147) PT147 pressure transmitter w/5 ft. capillary* P4L = PT147 Less Pulsation Dampener*

*For capillary greater than 5 ft., specify in 5 ft. increments following designator, example: P415

P6 = (PT167) PT167 pressure transmitter direct mount P6S = (PT167SS) PT167 stainless steel

Dials: Dials are dual scale psi and kPa/MPa. Single scale and custom dials available.

CSA Certified Models: 45PE Series models with pressure range thru 5000 psig (34.4 MPa) [344 bar] are CSA certi- fied for Non-Hazardous locations, except options BC, CC, ES, LC and OS. Explosion-proof “EX” models with pressure range thru 5000 psig (34.4 MPa) [344 bar] are CSA certified for Hazardous locations. 45PEBP models are not CSA certified.

45PE Series

Typical Wiring Diagram

LOW SWITCH

HIGH SWITCH

N.C.–Orange

N.C.–Black

3

6

N.O.–Blue

N.O.–Brown

2

5

Common–Red

Common–Yellow

1

4

Contact Rating: 2-SPDT snap-switches (one for high and low pressure); 2 A @ 250 VAC

NOTE: Diagram shows the pointer in the at rest (shelf) position.

FWMurphy

P.O. Box 470248

Tulsa, Oklahoma 74147 USA

(918)317-4100 fax (918) 317-4266

e-mailsales@fwmurphy.com www.fwmurphy.com

CONTROL SYSTEMS & SERVICES DIVISION P.O. Box 1819; Rosenberg, Texas 77471; USA

(281)342-0297 fax (281) 341-6006 e-mailsales@fwmurphy.com

MURPHY DE MEXICO, S.A. DE C.V.

Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P.; México 78384

+52-444-8206264 fax +52-444-8206336 e-mailventas@murphymex.com.mx www.murphymex.com.mx

FRANK W. MURPHY, LTD.

Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K. +44 1722 410055 fax +44 1722 410088 e-mailsales@fwmurphy.co.uk www.fwmurphy.co.uk

MURPHY SWITCH OF CALIFORNIA

41343 12th Street West

Palmdale, California 93551-1442; USA

(661)272-4700 fax (661) 947-7570 e-mailsales@murphyswitch.com www.murphyswitch.com

MACQUARRIE CORPORATION 1620 Hume Highway Campbellfield, Vic 3061; Australia

+61 3 9358-5555 fax +61 3 9358-5558 e-mailmurphy@macquarrie.com.au

 

E

 

 

D

 

 

 

 

R

 

 

 

 

 

 

E

 

 

GISTER

 

 

 

 

 

 

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

Printed in U.S.A.

45PE-96002B 2 of 2

Page 2
Image 2
Murphy How to Order, 45PEBP - 4 - S- 100 - EX, 45PE Series Typical Wiring Diagram, FWMurphy, Base Model, Range