Murphy EMS447 Model, EMS447 - VFD - RBL - C - V - A94035, EMS448 Model, How to Order, Warranty

Models: EMS447 EMS448

1 2
Download 2 pages 33.18 Kb
Page 2
Image 2
EMS447 Model

EMS447 Model

How to Order

Front

EMS

 

 

 

Side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-5/8 in.

2-7/8 in.

 

 

 

 

 

(67 mm)

 

 

(73 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To order the EMS use the model number designation diagram below.

EMS447 – VFD – RBL – C – V – A94035

5-43/64 in.

(144 mm)

Rear

¥¥¥¥¥¥¥¥¥¥¥¥¥¥

¥¥¥¥¥¥¥¥¥¥¥¥¥¥

5-11/32 in.

(135 mm)

 

 

 

 

 

4-5/16 in.

 

 

 

 

 

 

 

.540 in.

 

(110 mm)

 

 

 

 

 

 

 

 

 

8 in. (203 mm)

 

 

 

 

(13.716 mm)

Clearance for Connectors

Mounting Hole

2-5/8 in.

(67 mm) 2-43/64 in.

(68 mm)

5-3/8 in.

(137 mm)

Model

EMS447 = 1/4DIN aluminum box EMS448 = NEMA4X weatherproof

DisplayBlank = default LCD

VFD = vacuum fluorescent

LightingBlank = default green
Specify Program NumberA94035 = basic programCustom programming is availableCaseBlank = non-vented V = vented caseClock

Front

EMS448 Model

Side

8-15/16 in.

 

4-3/4 in.

 

(227 mm)

 

 

RBL = red black lighting (faceplate reads MEMIS)
Blank = without clock C = clock function

 

 

 

8-1/2 in.

 

 

 

(121 mm)

 

 

 

(216 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EMS

6-7/8 in.

 

(175 mm)

 

4 in.

 

(102 mm)

 

5/16 x 1/2 in. (8 x 13 mm)

 

Mounting Holes, 4-Places

Accessories

Required to complete the installation

EMS25TB = Plug-in terminal block assembly

EMS25RM = Rail mount DIN type terminal block

EMS25CAR2 = Ribbon cable with 2 male D-subminiature connectors

EMS25CAS = Male connector with 9 ft. (2.74 m) long color coded cable EMS25MS = Solder type male D-subminiature connector

S449-1 = Relay board instead of S449-3 realy board.

S449-2 = Relay board (EMS447 only)

S449-4 = Relay board (EMS447 only)

Standard length ribbon cable is 2 ft. (610 mm). Specify in feet for other lengths. Example: EMS25CAR4 (for 4 feet long).

EMS447 Optional Wiring Harness and Relay Boards

 

EMS25TB

 

13

 

1

25

14

GND

EMS25MSEMS447

• • • • • • • • • • • • • • • • • • • • • • • • • • • •

• • • • • • • • • • • • • •

• • • • • • • • • • • • • •

EMS25CAS

1

11

2

12

3

13

4

14

5

15

6

16

7

17

8

18

9

19

10

20

How to Order S449-2

• • • • • • • • • • • • • •

 

OFF

 

TEST

AUTO

 

• • • • • • • • • • • • • •

 

 

 

21

31

 

 

22

32

 

 

23

33

 

 

24

34

 

 

25

35

 

 

26

36

 

 

27

37

 

 

28

38

 

 

29

39

 

 

30

40

EMS25CAR2

• • • • • • • • • • • • • • • • • • • • • • • • • • • •

EMS25TBCAR2

• • • • • • • • • • • • • •

• • • • • • • • • • • • • •

 

 

EMS25RM

 

 

 

 

• • • • • • • • • • • • • •

 

 

 

 

• • • • • • • • • • • • • •

 

14 15

16

17

18

19

20 21

22

23

24

25 26

1

2

3

4

5

6

7

8

9

10 11

12 13

S449-4

• • • • • • • • • • • • • •

• • • • • • • • • • • • • •

1

11

2

12

3

13

4

14

5

15

6

16

7

17

8

18

9

19

10

20

 

OFF

TEST

AUTO

 

21

31

 

22

32

 

23

33

 

24

34

 

25

35

 

26

36

 

27

37

 

28

38

 

29

39

 

30

40

Warranty

A limited warranty on materials and workmanship is given with this FW Murphy product.

A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm

FW MurphyP.O. Box 470248

Tulsa, Oklahoma 74147 USA +1 918 317 4100

fax +1 918 317 4266 e-mailsales@fwmurphy.com www.fwmurphy.com

CONTROL SYSTEMS & SERVICES DIVISION P.O. Box 1819; Rosenberg, Texas 77471; USA +1 281 633 4500 fax +1 281 633 4588 e-mail sales@fwmurphy.com

MURPHY DE MEXICO, S.A. DE C.V.

Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P.; México 78384

+52 444 8206264 fax +52 444 8206336 Villahermosa Office +52 993 3162117 e-mailventas@murphymex.com.mx www.murphymex.com.mx

FRANK W. MURPHY, LTD.

Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K. +44 1722 410055 fax +44 1722 410088 e-mailsales@fwmurphy.co.uk www.fwmurphy.co.uk

MURPHY SWITCH OF CALIFORNIA41343 12th Street WestPalmdale, California 93551-1442; USA

+1 661 272 4700 fax +1 661 947 7570 e-mailsales@murphyswitch.com www.murphyswitch.com

MACQUARRIE CORPORATION 1620 Hume Highway Campbellfield, Vic 3061; Australia

+61 3 9358 5555 fax +61 3 9358 5558 e-mailmurphy@macquarrie.com.au

 

E

 

 

D

 

 

 

 

R

 

 

 

 

 

 

E

 

 

GISTER

 

 

 

 

 

 

USA–ISO 9001:2000 FM 28221

UK–ISO 9001:2000 FM 29422

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

Bulletin EMS-92199B page 2 of 2

Printed in U.S.A.

Page 2
Image 2
Murphy EMS447 Model, EMS447 - VFD - RBL - C - V - A94035, EMS448 Model, EMS447 Optional Wiring Harness and Relay Boards