Installation Instructions for Level Maintainers

Installation Instructions for Level Maintainers

Model Series LM300

Read the following instructions before installing. A visual inspection of this product for damage during shipping is recommended before mounting. These installation instructions are intended for all LM300 series models.

LM-92164N

Revised 10-03

Section 15

(00-02-0176)

GENERAL INFORMATION

WARNING

BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT

Disconnect all electrical power to the machine.

Make sure the machine cannot operate during installation.

Follow all safety warnings of the machine manufacturer.

Read and follow all installation instructions.

LM300: Level Maintainer only (no switches).

LM301: Low switch contacts for low level shutdown or alarm. Four wires, SPDT.

LM302: Two switches for low and high level shutdown or alarm. Four wires, DPST, wired N.O. in normal operating ranges.

LM303: Two switches for low and high level shutdown or alarm. Four wires, DPST, wired N.C. in normal operating ranges.

LM304: Two switches. Alarm before shutdown on low level and shutdown on low-low level. Four wires, DPST, wired N.O. in normal operating ranges.

LM305: Two switches. Alarm before shutdown on low level and shutdown on low- low level. Four wires, DPST, wired N.C. in normal operating ranges.

Specifications

Case/Cover: Die cast aluminum.

Switch Housing: Aluminum.

Approval Rating: LM301 thru LM305 : CSA certified†† for non hazardous locations. Enclosure Type 4 certified.

LM301-EX thru LM305-EX:CSA certified†† for Class I, Groups C and D; Class II, Groups F and G hazardous locations. Enclosure Type 4 certified.

Float: Rigid polyurethane foam. Polyurethane coated.

Maximum Ambient Temperature: 250°F (121°C)

Oil Inlet Connection: Top entry 1/2-14 NPT with built-in filter screen (removable for cleaning).

Inlet Orifices: 1/4 in. (6 mm) standard. 1/8 in. (3 mm) available.

Wire (switch models): 18 AWG x 13 in. (1.0 mm2 x 330 mm).

Maximum Inlet Pressure (MIP):

Max. Differential: 2 in. (51 mm) between running and stationary oil level. 30 psi (207 kPa) [2.07 bar].

with 1/8 in. (3 mm) orifice. 15 ft. oil (4.6 m oil)

with 1/4 in. (6 mm) orifice.

Maximum Case Pressure (MCP): 15 psi (103 kPa) [1.03 bar].

Orifice Seal: Buna-N Thumb-Valve™

Switch Contact: Silver, SPDT snap acting, 10A @ 125, 250VAC; 10A @ 30VDC.

(1 only for low level; 2 only for high & low; or 2 only for low with alarm before shutdown)

LM301-EX

Shown with optional hose kit fittings

Model Series LM300**

Patent 5493086

Outlet Connection: 3/4-14 NPT left side, right side, and bottom.

Crankcase Balance Vent Fitting: 1/2-14 NPT.

Mounting: Accepts Murphy pipe mounting or universal mounting brackets.

Lens: Clear “Frog Eye” non-staining, high impact, high temperature nylon; UV and heat stabilized.

Dial: High visibility white background with green and white “index” lines for normal level indication.

Test Knob: Rotate to test switch operation. Turn clockwise for low level test and turn counterclockwise for high level test.

Flow Rate Test: Using SAE 30 @ 32°F (0°C).

Orifice

Pressure

Flow Rates

Diameter

 

 

1/4 in.*

4 ft. oil – 15 ft. oil

4.7 GPH - 31.0 GPH

(6 mm)

(1.2 m oil – 4.6 m oil)

(17.8 LPH - 117.3 LPH)

1/8 in.

10 psig – 30 psig

16.9 GPH - 32.1 GPH

(68.9 kPa – 207 kPa)

(3 mm)

[.69 – 2.07 bar]

(63.7 LPH - 121.5 LPH)

 

 

 

 

 

*Standard

NOTE: Friction losses due to piping NOT considered.

Optional Hose Kit: 15000355

Quantity Description

11/2 in. (13 mm) I.D. x

3 ft. (914 mm) long hose

11 in. (25 mm) I.D. x

3 ft. (914 mm) long hose

21/2 in. (13 mm) worm gear clamp

21 in. (25 mm) worm gear clamp

21/2 NPT x 1/2 in. (13 mm) barbed fitting

23/4 NPT x 1 in. (25 mm) barbed fitting

††CSA certified with switch contacts rated at 10 A @ 250 VAC (standard).

**Products covered by this bulletin comply with EMC Council directive 89/336/EEC regarding electromagnetic compatibility except as noted.