Detail E
Turn to Raise the Pointer
Turn to Lower the Pointer
Power
Cable
Tubing
Ferrule
Compression
Nut
Detail D
Pump Panel
Sensor Fitting

INSTALLATION Continued

Installing the CKBO Check Valve

 

 

 

 

The optional CKBO check valve is designed

 

 

 

 

 

 

 

 

 

 

to prevent product from backing up into the

 

 

Detail C

 

 

 

 

 

 

 

 

 

 

 

 

gage(s). We recommend installing the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CKBO valve at top of the tank plug as

 

 

 

 

 

 

 

 

 

 

Tubing

 

 

 

 

 

 

 

 

 

 

 

1/4 NPTM

 

 

follows (refer to Detail C):

 

 

 

 

straight

 

 

 

 

 

 

1. Determine a location for the valve.

 

 

fitting

 

 

 

 

 

Valve

 

Check

 

 

 

 

 

 

Flat

Use of sealant on all fitting

 

 

 

 

 

 

 

 

 

 

 

T

 

 

threads is strongly suggested.

 

Valve

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

N

 

 

2. Attach CKBO to the tank plug

1/2 NPTM to

 

 

 

 

K

 

 

 

 

 

 

 

 

 

using wrench on valve flats.

1/4 NPTF

 

 

 

 

 

 

1/4 NPTM

 

Reducer

 

 

 

 

 

 

 

 

 

 

See markings on the valve body

 

 

Ferrule

 

 

 

 

straight fitting

for positioning.

 

 

 

 

 

 

Ferrule nut

 

 

 

 

 

 

 

 

 

 

 

Hole Plug

 

 

 

3. Attach tubing to CKBO as shown.

 

 

 

 

 

UTKN Tank Plug

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Securely tighten all fittings.

 

 

 

 

 

 

 

 

 

 

or tank top

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All connections must be air tight.

 

 

 

 

 

 

 

 

 

 

 

 

Installing the SMPA/SMPA230 Pump Assembly The pump assembly should be installed near the SM or SMVR panel. Connect the pump as follows (refer to Fig. 3 and 4 also see Detail D):

1. Before connecting the tubing from the SM or SMVR panel to the pump assembly, make sure the tubing reaches the pump assembly sensor fitting.

2. Connect the end of the tubing to the sen-

sor fitting as shown at right (Detail D). Tubing should be continuous length without splices.

3. The pump assembly includes a power cable, 16 AWG (1.5 mm2), 8 ft. (2.4 m) long. Connect the cable to 120 VAC or 230 VAC power source.

The pump assembly has a pressure SWICHGAGE®

with low and high pressure set points. When the gage pointer reaches the low pressure set point, the pump starts to built up purge pressure. When the pointer reaches the high set point, sufficient volume is reached stopping the pump. The set points are factory pre-set for your convenience.

Resetting the Pointer

CAUTION: SM and SMVR models are precalibrated in feet of static pressure above gage connection. Pointer MUST be reset to zero.

After the SM/SMVR complete system has been connected, reset the pointer for proper level indication, proceed as follows

(see Fig. 5 and Detail E):

1.Determine actual product level by any reliable means and record this value.

2. Very carefully remove the retaining ring

guarding against its spring-action, it can cause injuries. Remove the lens also.

3. Carefully hold the pointer, as shown at right, making sure not to bend it.

4. With a small screwdriver, turn the setting screw to corresponding stick reading value

recorded in step 1.

Clockwise to raise the pointer — counter clockwise to lower the pointer.

5. Replace the lens and snap ring.

Fig. 3 SM Panel Tubing Configuration

(SM2 Model shown)

FEET

FEET

MURPHY

MURPHY

LEVELGAGE

LEVELGAGE

To Pump

Assembly

 

To Tank 2 Plug

 

To Tank 1 Plug

Sensor Fitting

 

Sensor Fitting

 

 

 

To Tank 1 Plug

To Tank 2 Plug

 

Vapor Recovery

Vapor Recovery

 

Fitting

Fitting

Fig. 4

Pump Assembly

 

 

 

 

 

 

Pressure SWICHGAGE®

 

 

 

Y

S WICH

G

 

 

 

H

 

A

 

P

 

 

 

 

R

 

 

 

 

G

 

U

 

PSI

 

E

 

M

 

 

®

 

20

 

40

60

 

100

 

 

 

 

 

 

0

 

 

 

 

 

 

300

 

 

 

0

 

 

 

 

 

 

kPa

 

 

 

 

 

 

 

 

 

Low trip point

 

 

High trip point

 

adjustment

 

 

adjustment

120 VAC or 230 VAC

Tubing to SM Panel

Fig. 5

Snap Ring

Pointer

FEET

FEET

 

 

MURPHY

MURPHY

LEVELGAGE

LEVELGAGE

Read Button

UNLEADED

UNLEADED

3

Page 3
Image 3
Murphy SM4VR, SM2VR, SM1VR, SM3VR dimensions Detail C, Installing the Ckbo Check Valve, Resetting the Pointer

SM3, SM4VR, SM3VR, SM2VR, SM1VR specifications

Murphy SM series engines, including the SM1, SM2, SM4, SM1VR, and SM2VR, represent a comprehensive range of power solutions designed for diverse applications, primarily in the industrial sector. Each variant is engineered with unique features and technologies catered to meet specific performance demands.

Starting with the Murphy SM1, this engine is lauded for its compact size and efficiency. It employs a four-stroke cycle, providing a balance between power output and fuel consumption. The SM1 is equipped with advanced ignition systems and features a robust cooling mechanism, ensuring operational stability even under strenuous conditions.

The SM2, a step up from its predecessor, introduces enhanced displacement, resulting in increased horsepower. This model incorporates an advanced fuel injection system, promoting better fuel atomization and improved combustion efficiency. Additionally, the SM2 boasts a durable construction, which results in longevity and reduced maintenance needs.

The SM4 caters to applications demanding higher power outputs. Its design embraces a turbocharged configuration, which enables significant boosts in torque and horsepower. Featuring an integrated engine management system, the SM4 optimizes fuel efficiency and minimizes emissions, making it an environmentally friendly choice for heavy-duty applications.

Next, the SM1VR and SM2VR models are part of Murphy's variable response series, designed for more versatile operations. Both models include a variable intake system, allowing for adjustments in engine performance based on load conditions. This technology not only enhances fuel economy but also ensures a smoother power delivery across various operational settings.

Both the SM1VR and SM2VR come equipped with advanced monitoring systems, enabling real-time assessment of engine performance parameters. This feature is crucial for industries where operational efficiency and uptime are paramount. Enhanced diagnostic tools help in predictive maintenance, minimizing the risk of unforeseen breakdowns while extending the product's lifespan.

Overall, Murphy's SM series engines exemplify a blend of power, efficiency, and technology, making them an attractive choice for various industrial applications. Their commitment to innovation and quality ensures that operators have access to reliable and effective power solutions tailored to their specific needs. Whether for general industrial use or specialized applications, Murphy continues to lead the way in engine performance and reliability.