Your Installer has assigned a User 1 Code which may be used to not only Arm and Disarm the system, but
also to enter the User Program Mode, where you can program other user codes. The following explains
how you will use this code to program or erase additional user codes.

Entering the User Program Mode

Press A followed by 8 and then enter the User 1 code. The Armed, Status and üüSystem Lights will
flash, and the keypad will beep 4 times. You are now in the User Program mode. Zone lights 1 through
6 will light to indicate any User Codes presently programmed.

Programming / Reprogramming User Codes

1Press the User number to be programmed. (For example, press 2 to program the User 2 code.).
The keypad will beep 2 times and the corresponding Zone light will flash to indicate the user
number you are about to program.
2Press in the 4 digits of the new User 2 code, the keypad will beep 4 times.

3If there are more user codes to be programmed, return to step 1 above, otherwise, go to Exiting the

User Program Mode below.

Erasing a User Code

1Press the User number to be erased. The keypad will beep 2 times and the corresponding Zone light
will flash to indicate the user number you are about to erase.
2Press D . The zone light will go out to indicate that the user code has been erased.
3If there are more user codes to be erased, return to step 1 above, otherwise, go to Exiting the user
Program Mode below.

Exiting the User Program Mode

When you are done programming or erasing User codes, press b to Exit the User Program Mode.
Programming User Codes
FIRE
AC
SYSTEM
READY
ZONE 3
ZONE 1
ZONE 2
ZONE 5
ZONE 6
ZONE 4
ARMED
14
Oi218a.pub
page 14 Thursday, December 18, 1997 18:29