![HOT AIR](/images/new-backgrounds/49344/4934417x1.webp)
P r o d u c t S p e c i f i c a t i o n s
P r o d u c t S p e c i f i c a t i o n s
Maximum Heating Efficiency
Model | Fuel | BTU Input | BTU Output | AFUE | Steady State |
Natural Gas | 35,000 | 28,350 | 72% | 81% | |
| Propane | 33,000 | 26,400 | 72% | 80% |
BGD48N | Natural Gas | 36,000 | 23,500 | 62% | 65% |
| Propane | 36,000 | 23,500 | 62% | 65% |
BGD40N | Natural Gas | 30,000 | 20,400 | - | 68% |
| Propane | 30,000 | 20,400 | - | 68% |
GD45N | Natural Gas | 45,000 | 36,900 | - | 82% |
| Propane | 40,000 | 33,200 | 67.3% | 83% |
Natural Gas | 28,500 | 19,500 | 64% | 68.5% | |
| Propane | 24,000 | 16,000 | 61.5% | 67% |
BGD38NT | Natural Gas | 26,000 | 16,750 | 57% | 64.4% |
| Propane | 26,000 | 17,200 | 58% | 66.2% |
GD36NTR | Natural Gas | 26,000 | 22,400 | 73% | 86% |
| Propane | 26,000 | 22,800 | 74% | 88% |
GD34NT | Natural Gas | 24,500 | 19,500 | - | 81.3% |
| Propane | 24,500 | 19,500 | - | 81.3% |
GD33NR | Natural Gas | 22,000 | 17,000 | 63% | 77.2% |
| Propane | 22,000 | 17,500 | 63% | 79.4% |
Years of research, design and testing have enhanced optimum performance allowing Napoleon products to achieve some of the highest heater rating efficiencies on the market. Our products continuously surpass industry standards not only in appearance but in efficiency and performance.
| I n s t a l l a t i o n V e r s a t i l i t y |
• No need for costly foundation or brick work | • In Canada, approved for R2000 advanced housing |
• Ground level and above installations | • Basement installations, even below grade using a Periscope |
• Zero Clearance to combustibles | • Also approved with Simpson |
• Suitable for mobile home installations | • Approved for bedroom, bathroom & bedsitting room installations |
| H e a t i n g F l e x i b i l i t y | |
HOT AIR | THERMOSTAT | |
DISTRIBUTION KIT | Optional thermostatic control maintains adjacent | |
room temperature for even | ||
With the hot air distribution kit and its | ||
greater convenience. | ||
independent fan control, you are | ||
| ||
offered a choice of distributing a por- |
| |
tion of the heat generated from your |
| |
fireplace either to other rooms, adding |
| |
to your overall home comfort ... | BLOWER | |
OR | ||
When you want to extract maximum heat an optional | ||
when fireplace heating | heat circulating blower offers increased heating efficiency. | |
efficiency is secondary to | A thermal sensor switch automatically turns blower on | |
the ambiance of a fire, | and off and a variable speed control is designed to be | |
disperse it outdoors ... | installed in the bottom of the unit or on a wall. | |
ideal for entertaining. |
| |
| ® | |
| QUALITY FIREPLACES |
16
| BGD48N | BGD40 | GD45N | GD36NTR | GD34NT | GD33NR | |||
Heater rated | Y | Y | Y | Y | Y | N | Y | Y | Y |
Wall Furnace rated | Y | N | N | Y | N | N | Y | N | Y |
Vents, vertically or horizontally | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Hinged door assembly | Y | N | Y | Y | N | Y | Y | N | N |
Venting | Top | 45˚ | 45˚ | 45˚ | 45˚ | Top | Rear/Top | Top | Rear |
PHAZER® logs | S | S | S | S | S | S | S | S | S |
Ceramic glass | S | - | - | S | - | - | S | S | S |
Tempered Glass | - | S | S | - | S | S | - | - | - |
Door Size HxW (in inches) | 23 x 31 5/8 | 26 1/2 x 44 1/2 | End 19 3/8 x 17 1/8 | 22 1/4 x 39 1/2 | 22 x 38 5/8 | 23 x 31 5/8 | 19 3/8 x 31 5/8 | 16 x 30 5/8 | 16 x 30 5/8 |
|
|
| Face 19 3/8 x 31 5/8 |
|
|
|
|
|
|
100% safety shut off | S | S | S | S | S | S | S | S | S |
Zero clearance | S | S | S | S | S | S | S | S | S |
No hearth extension required | S | S | S | S | S | S | S | S | S |
Sealed combustion chamber | S | S | S | S | S | S | S | S | S |
Presidents Limited Lifetime Warranty S | S | S | S | S | S | S | S | S | |
|
|
|
|
|
|
|
|
|
|
STANDARD: S | OPTIONAL: O | YES: Y | NO: N | N/A: - |
|
|
|
|
|
Tested as a heater and/or wall furnace.Tested to Z21.86, Z21.88 and CSA 2.32, CSA 2.33 in Canada and United States: CSA 2.33 and ANSI Z21.88 or CSA
A c c e s s o r i e s
GD33NR | |||||||||
Decorative brick panels | - | - | S | S | - | - | O | O | O |
Old town red brick panels | S | - | - | - | - | - | O | - | - |
Metal brick panels | - | O | - | - | O | O | O | O | O |
Herringbone | - | - | - | - | - | - | O | - | - |
O | - | - | S | O | O | O | O | ||
Polished brass trim | O | O | O | - | O | O | O | O | O |
Antique brass trim | - | - | O | - | O | - | O | O | O |
Brushed stainless steel trim | O | O | O | - | O | O | O | O | O |
Textured black bevelled trim | O | - | - | - | - | O | O | - | - |
Polished brass 3D and bevelled trim | O | O | O | O | O | O | O | O | O |
Antique brass 3D and bevelled trim | O | - | O | - | - | O | O | - | - |
Brushed stainless steel 3D and bevelled trim O | O | O | O | O | O | O | O | O | |
Polished brass rectangular door trim | - | - | O | - | - | - | O | O | O |
Bay window kit | - | - | - | O | - | - | O | - | - |
Bay front kit with screen | O | - | O | - | - | O | O | O | O |
Arched door facia | - | - | O | - | - | - | O | - | - |
Webbed arch door facia kit | - | - | O | O | - | - | O | O | O |
Ornamental face plates | O | - | - | - | - | - | - | - | - |
Arched face plate with double |
|
|
|
|
|
|
|
|
|
door safety screen | O | - | - | - | - | - | - | - | - |
Polished brass louvres | O | O | O | O | O | O | O | O | O |
24 karat gold plated louvres | O | - | - | - | - | O | - | - | - |
Brushed stainless steel louvres | O | O | O | O | O | O | O | O | O |
Black louvres | O | O | O | O | O | O | O | O | O |
Antique brass louvres | - | - | O | - | - | - | O | - | - |
Ornamental insets• | O | O | O | - | O | - | O | O* | O* |
Andirons | O | O | O | O | O | O | O | O* | O* |
Decorative door kits | - | - | O | O•• | - | - | O | - | - |
Cast iron surrounds••• | O | O | O••• | O | O | O | O | - | - |
Hot air distribution kit | O | O | - | O | O | O | O | O | O |
|
|
|
|
|
|
|
|
| |
with digital readout | O | O | O | O | O | O | O | O | O |
|
|
|
|
|
|
|
|
| |
remote control | O | O | O | O | O | O | O | O | O |
|
|
|
|
|
|
|
|
| |
remote (controls flame and blower) | O | O | O | O | O | O | O | - | - |
Wall thermostat | O | O | O | O | O | O | O | O | O |
Heat circulating blower | S | O | O | O | O | O | O | O | O |
S | S | S | S | S | S | S | S | S | |
Attached gas flex connector | - | S | - | - | S | - | - | - | - |
Night light | S | - | - | - | - | - | - | - | - |
•BGD42 and BGD48 available in Heritage only | •• Webbed arched only | ••• BGD40N (See thru model only) | *Suitable for bay front only |
|
|
|
17